Kwetsbaarheden verholpen in Siemens producten
view advisory published 2025-05-14
Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter en Versicharge
01
describes (31)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2025-40566US | critical9.8 | — | ||
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly… | ||||
| CVE-2025-40556US | — | — | ||
A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions… | ||||
| CVE-2025-40555US | — | — | ||
A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a s… | ||||
| CVE-2025-32454US | — | — | ||
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualizat… | ||||
| CVE-2025-31930US | —OT elevated | — | ||
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versio… | ||||
| CVE-2025-31929US | — | — | ||
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC… | ||||
| CVE-2025-30176US | — | — | ||
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All version… | ||||
| CVE-2025-30175US | — | — | ||
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All version… | ||||
| CVE-2025-30174US | — | — | ||
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All version… | ||||
| CVE-2025-26390US | — | — | ||
A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking… | ||||
| CVE-2025-26389US | critical9.8 | — | ||
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters requir… | ||||
| CVE-2025-24510US | — | — | ||
A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an atta… | ||||
| CVE-2025-24009US | — | — | ||
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authent… | ||||
| CVE-2025-24008US | —OT elevated | — | ||
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in… | ||||
| CVE-2025-24007US | —OT elevated | — | ||
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). Affected devices only provide weak password… | ||||
| CVE-2024-51447US | — | — | ||
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.2). The login implementation of the affected application contains an obse… | ||||
| CVE-2024-51446US | medium5.4 | — | ||
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The file upload feature of the affected application improperly saniti… | ||||
| CVE-2024-51445US | — | — | ||
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The affected application contains a XML External Entity Injection (XX… | ||||
| CVE-2024-51444US | — | — | ||
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The application insufficiently validates user input for database read… | ||||
| CVE-2024-23815US | —OT elevated | — | ||
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), De… | ||||
showing 20 of 31
02
references
External citations — patches, advisories, analysis.
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal
- Reference - ncscclearexternal