CVE-2025-31930
highpriority · track · 0OT risk · elevatedEPSS 0.003 · 20 %ileDEEUNLRUUSEPSS · scored 2026-10-23
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedIEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedUL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedVersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2)siemens_psirt
Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.
- FixedIEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedIEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedUL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
- FixedVersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2)cisa_csaf_ot
Update to V2.135 or later version. The latest version will be pushed to the device OTA if the charger is completely commissioned and connected to Siemens Device Management. Contact our Customer Service for further assistance or troubleshooting
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.3–8.8
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (695)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2025-0160Kwetsbaarheden verholpen in Siemens productenNL2025-05-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter en Versicharge
- SSA-556937SSA-556937: Multiple Vulnerabilities in VersiCharge AC Series EV Chargers2025-05-13csaf · siemens_psirtDE
VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens recommends countermeasures for products where fixes are not, or not yet available.
- ICSA-25-135-08Siemens VersiCharge AC Series EV Chargers2025-05-13icsa · cisa_csaf_otUS
VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (5)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/html/ssa-556937.htmlcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2025-31930cnnvd
- https://support.industry.siemens.com/cs/document/109827884/firmware-release-v2-500-30-for-versicharge-ac-series-?dti=0&lc=en-WWPatchcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-556937.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-556937.htmlnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.