CVE-2025-32454

highpriority · track · 0EPSS 0.002 · 8 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.18% (8th) EPSS
CVSS 7.8 · high
Is it mine?
666 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.4–7.8

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · NCSC-NL NL
v3.17.8highAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 1.8 · impact 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.04.4mediumCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (666)

Products and version ranges known to be affected.

06

advisories (6)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0160Kwetsbaarheden verholpen in Siemens productenNL2025-05-14csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter en Versicharge

  • NCSC-2025-0187Kwetsbaarheden verholpen in Siemens productenNL2025-06-10csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als RUGGEDCOM, SCALANCE, SIMATIC en Tecnomatix

  • SSA-486186SSA-486186: Out of Bounds Read Vulnerability in Tecnomatix Plant Simulation Before 24042025-06-10csaf · siemens_psirtDE

    Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • SSA-542540SSA-542540: Out of Bounds Read Vulnerability in Teamcenter Visualization2025-05-13csaf · siemens_psirtDE

    Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-135-06Siemens Teamcenter Visualization2025-05-13icsa · cisa_csaf_otUS

    Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-162-01Siemens Tecnomatix Plant Simulation2025-06-10icsa · cisa_csaf_otUS

    Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (8)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan