CVE-2025-40555

mediumpriority · track · 0EPSS 0.002 · 12 %ileDEEUNLUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.22% (12th) EPSS
CVSS 4.7 · medium
Is it mine?
548 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · ncsc_nl

EPSS · scored 2026-10-27

A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

The vendor does not plan to fix this; mitigate or replace.

  • No fix plannedAPOGEE PXC+TALON TC Series (BACnet)siemens_psirt

    Currently no fix is planned

  • No fix plannedAPOGEE PXC+TALON TC Series (BACnet)cisa_csaf_ot

    Currently no fix is planned

02

cvss

Technical severity, 0–10. One row per scoring source.

5.3
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 1.3–5.3

v3.14.7mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Lsecondary · productcert@siemens.com DEexploitability 2.8 · impact 1.4
v3.14.7mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Lsecondary · CISA US
v3.14.7mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Lsecondary · Siemens ProductCERT DE
v3.14.7mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Lsecondary · NCSC-NL NL
v4.05.3mediumCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:Lsecondary · ENISA EU
v4.05.3mediumCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.01.3lowCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:L/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (548)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0160Kwetsbaarheden verholpen in Siemens productenNL2025-05-14csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter en Versicharge

  • SSA-718393SSA-718393: Partial Denial of Service Vulnerability in APOGEE PXC and TALON TC Series (BACnet) Devices2025-05-13csaf · siemens_psirtDE

    APOGEE PXC and TALON TC Series (BACnet) Devices devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-25-135-14Siemens APOGEE PXC and TALON TC Series2025-05-13icsa · cisa_csaf_otUS

    APOGEE PXC and TALON TC Series (BACnet) Devices devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation. Siemens recommends countermeasures for products where fixes are not, or not yet available.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (3)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan