ICSA-24-256-10

icsaUScisa_csaf_ot

Siemens SINEMA

view advisory published 2024-09-10

SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.

01

describes (7)

Related CVEs.

IDseverity exploitable
CVE-2024-42344USmedium5.5—
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application inserts sensitive information into a log file which is reada…
CVE-2024-32006USmedium6.5—
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application does not expire the user session on reboot without logout. T…
CVE-2024-2466US——
libcurl did not check the server certificate of TLS connections done to a host specified as an IP address, when built to use mbedTLS. libcurl would wrongly avoid using the set hos…
CVE-2024-2398US——
When an application tells libcurl it wants to allow HTTP/2 server push, and the amount of received headers for the push surpasses the maximum allowed limit (1000), libcurl aborts t…
CVE-2024-2379US——
libcurl skips the certificate verification for a QUIC connection under certain conditions, when built to use wolfSSL. If told to use an unknown/bad cipher or curve, the error path…
CVE-2024-2004US—OT elevated—
When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic…
CVE-2023-46850UScritical9.8—
Use after free in OpenVPN version 2.6.0 to 2.6.6 may lead to undefined behavoir, leaking memory buffers or remote execution when sending network buffers to a remote peer.