CVE-2024-2004

mediumpriority · track · 1OT risk · elevatedEPSS 0.017 · 77 %ileDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.68% (77th) EPSS
CVSS 5.3 · medium
Is it mine?
98 products
Check your exposure
Who says so?
8 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-27

When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

5.3
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 3.2–5.3

v3.15.3mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:Lsecondary · CISA US
v3.13.7lowAV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.13.5lowCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:Nsecondary · ENISA EU
v3.13.5lowCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:Nsecondaryexploitability 2.1 · impact 1.4
v3.15.3mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:Lsecondary · Siemens ProductCERT DE
v3.13.2lowCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
v3.15.3mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:Lsecondary · NCSC-NL NL
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (98)

Products and version ranges known to be affected.

showing 20 of 98
06

advisories (14)

Vendor and ecosystem advisories describing this.

  • NCSC-2024-0320Kwetsbaarheden verholpen in Apple MacOSNL2024-07-30csaf · ncsc_nlNL

    Apple heeft kwetsbaarheden verholpen in MacOS.

  • NCSC-2024-0339Kwetsbaarheden verholpen in Microsoft MarinerNL2024-08-13csaf · ncsc_nlNL

    Microsoft heeft kwetsbaarheden verholpen in Mariner (Azure Linux).

  • NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.

  • NCSC-2024-0433Kwetsbaarheden verholpen in Siemens productenNL2024-11-12csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDCOM, SCALANCE, SIMATIC en SINEC.

  • SSA-331112SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP12024-11-12csaf · siemens_psirtDE

    SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.

  • SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).

  • SSA-417159SSA-417159: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP22024-09-10csaf · siemens_psirtDE

    SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.

  • WID-SEC-W-2024-0726cURL: Mehrere SchwachstellenDeutsch2024-03-26csaf · cert_bundDE

    Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in cURL ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder um Sicherheitsmaßnahmen zu umgehen.

  • WID-SEC-W-2024-1725Apple macOS: Mehrere SchwachstellenDeutsch2024-07-29csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Apple macOS ausnutzen, um seine Privilegien zu erhöhen, beliebigen Code mit Administratorrechten auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Daten zu modifizieren, den Benutzer zu täuschen, Sicherheitsmaßnahmen zu umgehen und vertrauliche Informationen offenzulegen.

  • WID-SEC-W-2025-0225Dell PowerProtect Data Domain: Mehrere SchwachstellenDeutsch2025-01-30csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Dell PowerProtect Data Domain ausnutzen, um erhöhte Rechte zu erlangen, einen Denial-of-Service-Zustand herbeizuführen und einen nicht näher spezifizierten Angriff durchzuführen.

  • ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).

  • ICSA-24-256-10Siemens SINEMA2024-09-10icsa · cisa_csaf_otUS

    SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.

  • ICSA-24-319-04Siemens SINEC NMS2024-11-12icsa · cisa_csaf_otUS

    SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.

  • CURL-CVE-2024-2004Usage of disabled protocol2024-03-27vendor · osvUS

    When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (36)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan