CVE-2024-32006
mediumpriority · track · 26EPSS 0.003 · 21 %ileDEEUNLRUUSEPSS · scored 2026-10-22
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application does not expire the user session on reboot without logout. This could allow an attacker to bypass Multi-Factor Authentication.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSINEMA Remote Connect Clientsiemens_psirt
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/ - FixedSINEMA Remote Connect Clientcisa_csaf_ot
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/ - MitigationSINEMA Remote Connect Clientsiemens_psirt
Instead of using the TOTP-based two-factor authentication mechanism, consider login with Smartcard/User certificate
- MitigationSINEMA Remote Connect Clientcisa_csaf_ot
Instead of using the TOTP-based two-factor authentication mechanism, consider login with Smartcard/User certificate
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 1.3–6.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (9)
Products and version ranges known to be affected.
- sinema_remote_connect_clientall versionsncsc_nlNLcpe:2.3:a:siemens:sinema_remote_connect_client:0:*:*:*:*:*:*:*
- siemens sinema remote connect clientall versionsncsc_nlNLcpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*
- siemens sinema remote connect client< 3.2nvdUScpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*
- siemens sinema remote connect client= 3.2nvdUScpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.
- SSA-417159SSA-417159: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP22024-09-10csaf · siemens_psirtDE
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
- ICSA-24-256-10Siemens SINEMA2024-09-10icsa · cisa_csaf_otUS
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
also known as (6)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (5)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/html/ssa-417159.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2024-32006/cnnvd