CVE-2023-46850
criticalpriority · track · 40EPSS 0.020 · 81 %ileDEEUNLRUUSEPSS · scored 2026-10-23
Use after free in OpenVPN version 2.6.0 to 2.6.6 may lead to undefined behavoir, leaking memory buffers or remote execution when sending network buffers to a remote peer.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSINEMA Remote Connect Clientsiemens_psirt
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/ - FixedSINEMA Remote Connect Clientcisa_csaf_ot
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (22)
Products and version ranges known to be affected.
- siemens sinema remote connect clientall versionsncsc_nlNLcpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*
- openvpn openvpn access server2.11.0 → 2.11.3nvdUScpe:2.3:a:openvpn:openvpn_access_server:*:*:*:*:*:*:*:*
advisories (4)
Vendor and ecosystem advisories describing this.
- NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.
- SSA-417159SSA-417159: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP22024-09-10csaf · siemens_psirtDE
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
- WID-SEC-W-2023-2872OpenVPN: Mehrere SchwachstellenDeutsch2023-11-09csaf · cert_bundDE
Ein entfernter authentifizierter Angreifer kann mehrere Schwachstellen in OpenVPN ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen oder vertrauliche Informationen offenzulegen.
- ICSA-24-256-10Siemens SINEMA2024-09-10icsa · cisa_csaf_otUS
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (14)
External citations — patches, advisories, analysis.
- https://community.openvpn.net/openvpn/wiki/CVE-2023-46850cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-46850/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/L3FS46ANNTAVLIQY56ZKGM5CBTRVBUNE/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/O54I7D753V6PU6XBU26FEROD2DSHEJQ4/cnnvd
- https://openvpn.net/security-advisory/access-server-security-update-cve-2023-46849-cve-2023-46850/cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.6836cnnvd
- https://www.debian.org/security/2023/dsa-5555cnnvd
- https://community.openvpn.net/openvpn/wiki/CVE-2023-46850enisa_euvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan