SSA-556937

csafDEsiemens_psirt

SSA-556937: Multiple Vulnerabilities in VersiCharge AC Series EV Chargers

view advisory published 2025-05-13

VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens recommends countermeasures for products where fixes are not, or not yet available.

01

describes (2)

Related CVEs.

IDseverity exploitable
CVE-2025-31930US—OT elevated—
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versio…
CVE-2025-31929US——
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC…
02

references

External citations — patches, advisories, analysis.

03

remediations (74)

  • No fix plannedIEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1)

    Currently no fix is planned

  • No fix plannedIEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0)

    Currently no fix is planned

  • No fix plannedUL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0)

    Currently no fix is planned

  • No fix plannedUL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2)

    Currently no fix is planned

  • No fix plannedUL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3)

    Currently no fix is planned

  • No fix plannedUL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3)

    Currently no fix is planned

  • No fix plannedVersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2)

    Currently no fix is planned

  • FixedIEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedIEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedUL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

  • FixedVersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2)

    Commission the charger and associate it to a VersiCloud group with Modbus configured to be off. If you are uncertain about whether the Modbus setting is on or off in the group you wish to use, contact Siemens support.

scry

Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.

Free scan