CVE-2022-29187
mediumpriority · track · 31EPSS 0.004 · 39 %ileDEEURUUSEPSS · scored 2026-10-27
Git is a distributed revision control system. Git prior to versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5, is vulnerable to privilege escalation in all platforms. An unsuspecting user could still be affected by the issue reported in CVE-2022-24765, for example when navigating as root into a shared tmp directory that is owned by them, but where an attacker could create a git repository. Versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5 contain a patch for this issue. The simplest way to avoid being affected by the exploit described in the example is to avoid running git as root (or an Administrator in Windows), and if needed to reduce its use to a minimum. While a generic workaround is not possible, a system could be hardened from the exploit described in the example by removing any such repository if it exists already and creating one as root to block any future attacks.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - Fixedphoenix_contact_psirt
Update to the latest 2023.0.0 LTS Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- FixedPLCnext Engineerphoenix_contact_psirt
Update PLCnext Engineer to 2023.6.
- FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note: Measures to protect network-capable devices with Ethernet connection
- MitigationPLCnext Engineerphoenix_contact_psirt
To mitigate aforementioned vulnerabilities the integrity and authenticity of the git configuration data must be ensured. Otherwise, we kindly advise you to refrain from using the version control feature in version lower than 2023.6
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.9–7.8
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (88)
Products and version ranges known to be affected.
advisories (7)
Vendor and ecosystem advisories describing this.
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- VDE-2023-001PHOENIX CONTACT: Multiple Vulnerabilities in PLCnext Firmware2023-02-14csaf · phoenix_contact_psirtDE
A new LTS Firmware release fixes known vulnerabilities in used open-source libraries. In addition, the following improvements have been implemented: HMI - Hardening against DoS attacks. - Hardening against memory leak problems in case of network attacks. WBM - Umlauts in the password of the 'User Manager' were not handled correctly. The password rule for upper and lower case was not followed. This could lead to unintentionally weaker passwords.- Hardening of WBM against Cross-Site-Scripting. User Manager - In security notifications 'SecurityToken' was always displayed as '0000000' when creating or modifying users.- Hardening of Trust and Identity Stores.
- VDE-2023-016Phoenix Contact: PLCnext Engineer Vulnerabilities in LibGit2Sharp/LibGit22023-08-08csaf · phoenix_contact_psirtDE
Several vulnerabilities have been discovered in the LibGit2Sharp or underlying LibGit2 library.This open-source component is widely used in a lot of products worldwide.The product is vulnerable to remote code execution, privilege escalation and tampering.PLCnext Engineer is using the LibGit2Sharp library to provide version control capabilities.
- WID-SEC-W-2022-0664git: Mehrere SchwachstellenDeutsch2022-07-12csaf · cert_bundDE
Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in git ausnutzen, um Sicherheitsvorkehrungen zu umgehen und beliebigen Code auszuführen.
- WID-SEC-W-2023-0561Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2023-03-02csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (58)
External citations — patches, advisories, analysis.
- http://seclists.org/fulldisclosure/2022/Nov/1cnnvd
- http://www.openwall.com/lists/oss-security/2022/07/14/1cnnvd
- https://cxsecurity.com/cveshow/CVE-2022-29187/cnnvd
- https://github.blog/2022-04-12-git-security-vulnerability-announcedcnnvd
- https://github.com/git/git/security/advisories/GHSA-j342-m5hw-rr3vcnnvd
- https://lists.debian.org/debian-lts-announce/2022/12/msg00025.htmlcnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/DDI325LOO2XBDDKLINOAQJEG6MHAURZE/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/DIKWISWUDFT2FAITYIA6372BVLH3OOOC/cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan