CVE-2026-110936

mediumpriority · act · 90OT risk · criticalKEV · exploitedEU KEV · CNWEPSS 0.002 · 14 %ileexploit · PoCDERUUS
grimoire priorityP0 · Act now
Exploitable?
Yes · in the wild
CISA KEV · 1 exploit · PoC
Likely / severe?
0.24% (14th) EPSS
CVSS 6.7 · medium
Is it mine?
4 products
Check your exposure
Who says so?
4 sources
fstec_bdu · cisa_csaf_ot · nvd · siemens_psirt

added 2026-10-20remediate by 2026-11-03

required action Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

EU KEVflagged by CNWreported 2026-10-19patched 2026-10-15

EPSS · scored 2026-10-23

Siemens Software Center Uncontrolled Search Path Element Vulnerability

A vulnerability has been identified in Siemens Software Center (All versions < V4.0.9.8). The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSiemens Software Centersiemens_psirt

    Update to V4.0.9.8 or later version (All existing versions of SSC will be auto updated on next startup. The latest version can also be downloaded in the respective link)

  • FixedSiemens Software Centercisa_csaf_ot

    Update to V4.0.9.8 or later version (All existing versions of SSC will be auto updated on next startup. The latest version can also be downloaded in the respective link)

02

cvss

Technical severity, 0–10. One row per scoring source.

8.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.7–8.4

v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · productcert@siemens.com DEexploitability 0.8 · impact 5.9
v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.16.7mediumAV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v4.08.4highCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.08.4highCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:A/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: active · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

exploits (1)

Public proof-of-concept and weaponised exploit code.

06

affected products (4)

Products and version ranges known to be affected.

07

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-580366SSA-580366: DLL Sideloading Vulnerability in Siemens Software Center2026-10-15csaf · siemens_psirtDE

    The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it.

  • ICSA-26-295-03Siemens Software Center2026-10-15icsa · cisa_csaf_otUS

    The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it.

08

also known as (2)

Other names and identifiers for this entity.

09

sources

Which sources assert this record, and when.

10

references (3) nvd

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan