CVE-2026-9128
highpriority · track · 30EPSS 0.002 · 6 %ileDEEURUUSEPSS · scored 2026-10-24
A code execution security issue exists within Studio 5000 Logix Designer® due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedStudio 5000 Logix Designercisa_csaf_ot
Studio 5000 Logix Designer: V36.00, 35.01, 34.03, 33.03, 32.05 (CVE-2026-9128)
- MitigationStudio 5000 Logix Designercisa_csaf_ot
Customers using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell Automation's security best practices (https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight).
https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.1–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (32)
Products and version ranges known to be affected.
advisories (2)
Vendor and ecosystem advisories describing this.
- WID-SEC-W-2026-2336Rockwell Automation Studio 5000 Logix Designer: Mehrere Schwachstellen ermöglichen CodeausführungDeutsch2026-07-14csaf · cert_bundDE
Ein lokaler Angreifer kann mehrere Schwachstellen in Rockwell Automation Studio 5000 Logix Designer ausnutzen, um beliebigen Programmcode auszuführen.
- ICSA-26-202-10Rockwell Automation Studio 5000 Logix Designer2026-07-21icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow for a local attacker to execute arbitrary files, alter configurations, or execute arbitrary code.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (3)
External citations — patches, advisories, analysis.
- https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1783.htmlcnnvd
- https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1783.htmlenisa_euvd
- https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1783.htmlVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.