CVE-2026-9127

highpriority · track · 30OT risk · elevatedEPSS 0.002 · 4 %ileDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.15% (4th) EPSS
CVSS 7.5 · high
Is it mine?
28 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-24

A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.5
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.1–7.5

v3.17.5highCVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 0.8 · impact 6
v3.17.5highCVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.17.5highAV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:Hsecondary · ENISA EU
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · PSIRT@rockwellautomation.com
v4.04.1mediumCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (28)

Products and version ranges known to be affected.

showing 20 of 28
05

advisories (2)

Vendor and ecosystem advisories describing this.

  • WID-SEC-W-2026-2336Rockwell Automation Studio 5000 Logix Designer: Mehrere Schwachstellen ermöglichen CodeausführungDeutsch2026-07-14csaf · cert_bundDE

    Ein lokaler Angreifer kann mehrere Schwachstellen in Rockwell Automation Studio 5000 Logix Designer ausnutzen, um beliebigen Programmcode auszuführen.

  • ICSA-26-202-10Rockwell Automation Studio 5000 Logix Designer2026-07-21icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow for a local attacker to execute arbitrary files, alter configurations, or execute arbitrary code.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

08

references (3)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan