CVE-2022-33139
mediumpriority · track · 39EPSS 0.013 · 70 %ileDEEURUUSEPSS · scored 2026-10-26
A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC WinCC OA V3.16siemens_psirt
Enable server-side authentication (SSA) or Kerberos authentication for your WinCC OA project
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v316-1.html - FixedSIMATIC WinCC OA V3.17siemens_psirt
Ensure that server-side authentication (SSA) is enabled for your WinCC OA project (which is the default configuration); alternatively enable Kerberos authentication
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v317.html - FixedSIMATIC WinCC OA V3.18siemens_psirt
Ensure that server-side authentication (SSA) is enabled for your WinCC OA project (which is the default configuration); alternatively enable Kerberos authentication
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v318.html - FixedSIMATIC WinCC OA V3.16cisa_csaf_ot
Enable server-side authentication (SSA) or Kerberos authentication for your WinCC OA project
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v316-1.html - FixedSIMATIC WinCC OA V3.17cisa_csaf_ot
Ensure that server-side authentication (SSA) is enabled for your WinCC OA project (which is the default configuration); alternatively enable Kerberos authentication
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v317.html - FixedSIMATIC WinCC OA V3.18cisa_csaf_ot
Ensure that server-side authentication (SSA) is enabled for your WinCC OA project (which is the default configuration); alternatively enable Kerberos authentication
https://www.winccoa.com/downloads/detail/security-guideline-wincc-oa-v318.html - MitigationCerberus DMSsiemens_psirt
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- MitigationDesigo CCsiemens_psirt
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- MitigationDesigo CC Compactsiemens_psirt
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- MitigationCerberus DMScisa_csaf_ot
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- MitigationDesigo CCcisa_csaf_ot
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- MitigationDesigo CC Compactcisa_csaf_ot
See https://support.industry.siemens.com/cs/ww/en/view/109813389/ for a list of specific mitigations
- No fix availableCerberus DMSsiemens_psirt
Currently no fix is available
- No fix availableDesigo CCsiemens_psirt
Currently no fix is available
- No fix availableDesigo CC Compactsiemens_psirt
Currently no fix is available
- No fix availableCerberus DMScisa_csaf_ot
Currently no fix is available
- No fix availableDesigo CCcisa_csaf_ot
Currently no fix is available
- No fix availableDesigo CC Compactcisa_csaf_ot
Currently no fix is available
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 6.8–9.8
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (34)
Products and version ranges known to be affected.
advisories (4)
Vendor and ecosystem advisories describing this.
- SSA-111512SSA-111512: Client-side Authentication in SIMATIC WinCC OA2022-06-21csaf · siemens_psirtDE
SIMATIC WinCC OA implements client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated. Siemens recommends to enable server-side authentication (SSA) or Kerberos authentication for all WinCC OA projects, as documented in the WinCC OA Security Guideline. In SIMATIC WinCC OA server-side authentication is available since V3.15 (and offered as the default configuration since V3.17). Additional information can be found at: https://cert-portal.siemens.com/productcert/news.html?id=21.
- SSA-836027SSA-836027: Client-side Authentication in Desigo CC and Cerberus DMS2022-10-11csaf · siemens_psirtDE
Desigo CC and Cerberus DMS are based on SIMATIC WinCC OA and implement client-side only authentication for specific parts of their client-server communication. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated, as documented for SIMATIC WinCC OA in SSA-111512 [1]. Siemens recommends specific mitigations, documented in [2], for products where fixes are not, or not yet available. Additional details regarding these mitigations can be found in the chapter Additional Information. [1] https://cert-portal.siemens.com/productcert/html/ssa-111512.html [2] https://support.industry.siemens.com/cs/ww/en/view/109813389/
- ICSA-22-172-06Siemens WinCC OA2022-06-21icsa · cisa_csaf_otUS
SIMATIC WinCC OA implements client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated. Siemens recommends to enable server-side authentication (SSA) or Kerberos authentication for all WinCC OA projects, as documented in the WinCC OA Security Guideline. In SIMATIC WinCC OA server-side authentication is available since V3.15 (and offered as the default configuration since V3.17). Additional information can be found at: https://cert-portal.siemens.com/productcert/news.html?id=21.
- ICSA-22-286-16Siemens Desigo CC and Cerberus DMS2022-10-11icsa · cisa_csaf_otUS
Desigo CC and Cerberus DMS are based on SIMATIC WinCC OA and implement client-side only authentication for specific parts of their client-server communication. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated, as documented for SIMATIC WinCC OA in SSA-111512 [1]. Siemens recommends specific mitigations, documented in [2], for products where fixes are not, or not yet available. Additional details regarding these mitigations can be found in the chapter Additional Information. [1] https://cert-portal.siemens.com/productcert/html/ssa-111512.html [2] https://support.industry.siemens.com/cs/ww/en/view/109813389/
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (11)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-111512.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-836027.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-33139/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-172-06cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-286-16cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-WinCC-OA-privilege-escalation-via-Client-side-Authentication-38638cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.3046cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-111512.pdfenisa_euvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.