CVE-2019-6567

lowpriority · track · 22EPSS 0.003 · 23 %ileEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.30% (23rd) EPSS
CVSS 2.1 · low
Is it mine?
20 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSCALANCE X-200 switch family (incl.'SIPLUS NET variants)cisa_csaf_ot

    Update to V5.2.4 or later version https://support.industry.siemens.com/cs/ww/en/view/109767965

  • FixedSCALANCE X-200IRT switch family (incl.'SIPLUS NET variants)cisa_csaf_ot

    Update to V5.5.0 or later version https://support.industry.siemens.com/cs/ww/en/view/109792534/

  • FixedSCALANCE X-300 switch family (incl.'X408 and SIPLUS NET variants)cisa_csaf_ot

    Update to V4.1.3 or later version https://support.industry.siemens.com/cs/document/109773547

  • MitigationSCALANCE X-200 switch family (incl.'SIPLUS NET variants)cisa_csaf_ot

    Restrict access to config backups or archived device configuration files

  • MitigationSCALANCE X-200IRT switch family (incl.'SIPLUS NET variants)cisa_csaf_ot

    Restrict access to config backups or archived device configuration files

  • MitigationSCALANCE X-300 switch family (incl.'X408 and SIPLUS NET variants)cisa_csaf_ot

    Restrict access to config backups or archived device configuration files

  • MitigationSCALANCE X-414-3Ecisa_csaf_ot

    Restrict access to config backups or archived device configuration files

02

cvss

Technical severity, 0–10. One row per scoring source.

7.1
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–high · 2.1–7.1

v2.02.1lowAV:L/AC:L/Au:N/C:P/I:N/A:Nprimary · NVD / NIST USexploitability 3.9 · impact 2.9
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Nprimary · NVD / NIST USexploitability 1.8 · impact 3.6
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.17.1highAV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.15.1mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (20)

Products and version ranges known to be affected.

05

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-19-162-04Siemens SCALANCE X (Update B)2019-06-11icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.