CVE-2021-22681

highKEV · exploitedEPSS 0.636 · 99 %ileEURUUS
grimoire priorityP0 · Act now
Exploitable?
Yes · in the wild
CISA KEV
Likely / severe?
63.6% (99th) EPSS
CVSS 7.5 · high
Is it mine?
33 products
Check your exposure
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

added 2026-03-05remediate by 2026-03-26

required action Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

EPSS · scored 2026-10-16

Rockwell Multiple Products Insufficient Protected Credentials Vulnerability

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.

01

cvss

Technical severity, 0–10. One row per scoring source.

10.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.5–10

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USexploitability 10 · impact 6.4
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.010criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.110criticalAV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondaryexploitability 3.9 · impact 5.9
02

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: active · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (33)

Products and version ranges known to be affected.

showing 20 of 33
05

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-21-056-03Rockwell Automation Logix Controllers (Update A)2021-02-25icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to bypass the verification mechanism and connect with Logix controllers. Additionally, this vulnerability could enable an unauthorized third-party tool to alter the controller 's configuration and/or application code.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (7)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan