CVE-2017-13754

lowpriority · track · 33EPSS 0.039 · 90 %ileexploit · PoCEUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
3.88% (90th) EPSS
CVSS 3.5 · low
Is it mine?
6 products
Check your exposure
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-27

Cross-site scripting (XSS) vulnerability in the "advanced settings - time server" module in Wibu-Systems CodeMeter before 6.50b allows remote attackers to inject arbitrary web script or HTML via the "server name" field in actions/ChangeConfiguration.html.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedFactoryTalk Activation Managercisa_csaf_ot

    Rockwell Automation recommends users with affected versions of CodeMeter and/or FlexNet Publisher that were installed with FactoryTalk Activation Manager to update Factory Talk Activation Manager to v4.02. If unable to update FactoryTalk Activation Manager to v4.02, update CodeMeter to a compatible version of CodeMeter that is compatible with FactoryTalk Activation Manager.

  • MitigationFactoryTalk Activation Managercisa_csaf_ot

    Block all traffic to EtherNet/IP or other CIP protocol-based devices from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP and UDP and Port 44818/TCP and UDP, using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID 898270 available at: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1 (Login required).

02

cvss

Technical severity, 0–10. One row per scoring source.

5.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2.7–5.4

v2.03.5lowAV:N/AC:M/Au:S/C:N/I:P/A:Nprimary · NVD / NIST USexploitability 6.8 · impact 2.9
v3.05.4mediumCVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USexploitability 2.3 · impact 2.7
v3.02.7lowCVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:L/A:Nsecondary · CISA US
v3.05.1mediumCVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:Psecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

exploits (1)

Public proof-of-concept and weaponised exploit code.

05

affected products (6)

Products and version ranges known to be affected.

06

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-18-102-02Rockwell Automation FactoryTalk Activation Manager (Update B)2018-04-12icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow a remote attacker to access sensitive information, rewrite content, or cause a buffer overflow that could result in remote code execution.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

published 2017-09-07modified 2026-06-17
10

references (18)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan