CVE-2015-1014
mediumpriority · track · 29EPSS 0.005 · 39 %ileEUUSEPSS · scored 2026-10-28
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
No vendor fix yet; a mitigation is available.
- MitigationOFScisa_csaf_ot
Schneider Electric originally released advisory SEVD-2015-181-01 on its SCADA & MES Support secure Portal on May 29, 2015. This public web page release was delayed to allow users time to implement the patch recommended
- MitigationOFS v3.5cisa_csaf_ot
Schneider Electric originally released advisory SEVD-2015-181-01 on its SCADA & MES Support secure Portal on May 29, 2015. This public web page release was delayed to allow users time to implement the patch recommended
- MitigationOPC Factory Server (OSF)cisa_csaf_ot
Schneider Electric originally released advisory SEVD-2015-181-01 on its SCADA & MES Support secure Portal on May 29, 2015. This public web page release was delayed to allow users time to implement the patch recommended
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.4–7.3
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (11)
Products and version ranges known to be affected.
- schneider-electric opc factory server= 3.5nvdUScpe:2.3:a:schneider-electric:opc_factory_server:*:*:*:*:*:*:*:*
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-15-141-01ASchneider Electric OFS Server Vulnerability (Update A)2015-02-21icsa · cisa_csaf_otUS
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (5)
External citations — patches, advisories, analysis.
- http://www.schneider-electric.com/Patchcnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2015-1014cnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01enisa_euvd
- https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01MitigationThird Party AdvisoryUS Government Resourcenvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan