CVE-2020-15782
highPriorität · verfolgen · 41EPSS 0.052 · 92. PerzentilDEEURUUSEPSS · bewertet 2026-10-26
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- Behobenfesto_psirt
Update Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
https://support.industry.siemens.com/cs/de/en/view/109478459 - BehobenSIMATIC Drive Controller familysiemens_psirt
Update to V2.9.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)siemens_psirt
Update to V21.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759122/ - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
Update to V4.5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793280/ - BehobenSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Update to V2.9.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controllersiemens_psirt
Update to V21.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478528/ - BehobenSIMATIC S7-PLCSIM Advancedsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109795016/ - BehobenSINAMICS PERFECT HARMONY GH180 Drivessiemens_psirt
Drives manufactured on 2021-08-13 or later are not affected, as they contain a corrected version of the S7-1500 or S7-1200 CPU.
- BehobenSINUMERIK MCsiemens_psirt
Update to V6.15 or later version
- BehobenSINUMERIK ONEsiemens_psirt
Update to V6.15 or later version
- BehobenSIMATIC Drive Controller familycisa_csaf_ot
Update to V2.9.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)cisa_csaf_ot
Update to V21.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759122/ - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793280/ - BehobenSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Update to V2.9.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controllercisa_csaf_ot
Update to V21.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478528/ - BehobenSIMATIC S7-PLCSIM Advancedcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109795016/ - BehobenSINAMICS PERFECT HARMONY GH180 Drivescisa_csaf_ot
Siemens has identified the following specific mitigations and workarounds users can apply to reduce the risk:
- BehobenSINAMICS PERFECT HARMONY model 6SR4cisa_csaf_ot
Siemens has identified the following specific mitigations and workarounds users can apply to reduce the risk:
- BehobenSINAMICS PERFECT HARMONY model 6SR5cisa_csaf_ot
Siemens has identified the following specific mitigations and workarounds users can apply to reduce the risk:
- BehobenSINUMERIK MCcisa_csaf_ot
Update to V6.15 or later version
- BehobenSINUMERIK ONEcisa_csaf_ot
Update to V6.15 or later version
- BehobenSiemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic CP including S7 PLCcisa_csaf_ot
Update Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
https://support.industry.siemens.com/cs/de/en/view/109478459 - BehobenSiemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic MPS 200 Systemscisa_csaf_ot
Update Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
https://support.industry.siemens.com/cs/de/en/view/109478459 - BehobenSiemens Simatic S7-1500 / ET200SP < V2.9.2 installed on FESTO Didactic MPS 400 Systemscisa_csaf_ot
Update Siemens Simatic S7-1500 / ET200SP Firmware to V2.9.2 or higher
https://support.industry.siemens.com/cs/de/en/view/109478459 - MitigationSIMATIC Drive Controller familysiemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)siemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)siemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1500 Software Controllersiemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-PLCSIM Advancedsiemens_psirt
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSINAMICS PERFECT HARMONY GH180 Drivessiemens_psirt
Avoid compromise of the individually configured access protection password to the S7-1500 or S7-1200 CPU
- MitigationSINUMERIK MCsiemens_psirt
Limit access to port 102/tcp to trusted users and systems only
- MitigationSINUMERIK ONEsiemens_psirt
Limit access to port 102/tcp to trusted users and systems only
- MitigationSIMATIC Drive Controller familycisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)cisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)cisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-1500 Software Controllercisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSIMATIC S7-PLCSIM Advancedcisa_csaf_ot
Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for Industrial Security, especially: - Plant security: Physical prevention of access to critical components - Network security: Ensure that PLC systems are not connected to untrusted networks * System integrity: Configure, maintain and protect your device by applying applicable compensating controls and using built-in security capabilities
- MitigationSINUMERIK MCcisa_csaf_ot
Limit access to port 102/tcp to trusted users and systems only
- MitigationSINUMERIK ONEcisa_csaf_ot
Limit access to port 102/tcp to trusted users and systems only
- Kein Fix verfügbarSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)cisa_csaf_ot
Currently no remediation is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.5–9.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (66)
Betroffene Produkte und Versionsbereiche.
Advisories (8)
Hersteller- und Ökosystem-Meldungen dazu.
- FSA-202405Festo: Siemens S7-1500/ET200SP CPU used in Festo Didactic products contains a memory protection bypass vulnerability2024-09-09csaf · festo_psirtDE
Siemens SIMATIC S7-1200 and S7-1500 CPUs contained in various Festo Didactic products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks
- SSA-434534SSA-434534: Memory Protection Bypass Vulnerability in SIMATIC S7-1200 and S7-1500 CPU Families2021-05-28csaf · siemens_psirtDE
SIMATIC S7-1200 and S7-1500 CPU products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. Siemens has released updates for several affected products and strongly recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
- SSA-434535SSA-434535: Memory Protection Bypass Vulnerability in SINAMICS PERFECT HARMONY GH180 Drives2021-07-13csaf · siemens_psirtDE
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a memory protection bypass vulnerability in the integrated S7-1500 or S7-1200 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens provides new drives with the fix included and recommends specific countermeasures for older drives. The list of affected drive models can be found in the section "Additional Information".
- SSA-434536SSA-434536: Memory Protection Bypass Vulnerability in SINUMERIK ONE and SINUMERIK MC2021-07-13csaf · siemens_psirtDE
SINUMERIK ONE and SINUMERIK MC products are affected by a memory protection bypass vulnerability in the integrated S7-1500 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens has released updates for the affected products and recommends that customers update to the new version.
- ICSA-21-152-01Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update A)2021-05-28icsa · cisa_csaf_otUS
SIMATIC S7-1200 and S7-1500 CPU products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. Siemens has released updates for several affected products and strongly recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
- ICSA-21-194-13Siemens SINAMICS PERFECT HARMONY GH180 (Update A)2021-07-13icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could result in arbitrary code execution and unauthorized access to sensitive data.
- ICSA-21-194-17Siemens SINUMERIK ONE and SINUMERIK MC (Update A)2021-07-13icsa · cisa_csaf_otUS
SINUMERIK ONE and SINUMERIK MC products are affected by a memory protection bypass vulnerability in the integrated S7-1500 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens has released updates for the affected products and recommends that customers update to the new version.
- ICSA-25-182-01FESTO Didactic CP, MPS 200, and MPS 400 Firmware2024-09-09icsa · cisa_csaf_otUS
Siemens SIMATIC S7-1200 and S7-1500 CPUs contained in various Festo Didactic products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (15)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdfcnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-152-01cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-194-17cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-read-write-access-via-Memory-Protection-Bypass-35564cnnvd
- https://www.auscert.org.au/bulletins/ESB-2021.1900cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021053102cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan