CVE-2017-12741
highPriorität · verfolgen · 31EPSS 0.033 · 88. PerzentilDEEURUUSEPSS · bewertet 2026-10-26
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controllersiemens_psirt
Update to V4.1.1 Patch 05
https://support.industry.siemens.com/cs/ww/en/view/109755160 - BehobenDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200siemens_psirt
Update to V4.5
https://support.industry.siemens.com/cs/ww/en/view/109755151 - BehobenDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200Psiemens_psirt
Update to V4.5
https://support.industry.siemens.com/cs/ww/en/view/109750012 - BehobenSIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)siemens_psirt
Update to V1.0.2 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN BA (6ES7155-5AA00-0AA0)siemens_psirt
Update to V4.0.2 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN ST (6ES7155-5AA00-0AB0)siemens_psirt
Update to V4.1.0 or later version
- BehobenSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)siemens_psirt
Update to V1.1.0
https://support.industry.siemens.com/cs/ww/en/view/109763483 - BehobenSIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIMATIC ET 200SP IM 155-6 PN HS (6ES7155-6AU00-0DN0)siemens_psirt
Update to V4.0.1 or later version
- BehobenSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)siemens_psirt
Update to V4.2.0
https://support.industry.siemens.com/cs/ww/en/view/109760973 - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
Update to V4.2.3
https://support.industry.siemens.com/cs/us/en/view/109741461 - BehobenSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Upgrade to V2.0 or newer
https://support.industry.siemens.com/cs/us/en/ps/13717/dl - BehobenSIMATIC S7-1500 Software Controllersiemens_psirt
Upgrade to V2.0 or newer
https://support.industry.siemens.com/cs/us/en/view/109478528 - BehobenSIMATIC S7-200 SMARTsiemens_psirt
Update to V2.03.01
https://support.industry.siemens.com/cs/cn/en/view/109749409 - BehobenSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Update to V3.X.16 or later version
https://support.industry.siemens.com/cs/ww/en/ps/13752/dl - BehobenSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)siemens_psirt
Update to V6.0.8 or later version
- BehobenSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)siemens_psirt
Update to V6.0.6 or later version
- BehobenSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)siemens_psirt
Update to V7.0.2 or later version
- BehobenSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)siemens_psirt
Update to V8.2.1
https://support.industry.siemens.com/cs/ww/en/view/109476571 - BehobenSIMATIC TDC CP51M1siemens_psirt
Update to V1.1.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/27049282/ - BehobenSIMATIC TDC CPU555siemens_psirt
Update to V1.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109740119/ - BehobenSIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)siemens_psirt
Update to V2010 SP3 or later version and apply BIOS and Microsoft Windows updates
https://support.industry.siemens.com/cs/ww/en/view/109765109/ - BehobenSIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)siemens_psirt
Update to V2010 SP3 or later version and apply BIOS and Microsoft Windows updates
https://support.industry.siemens.com/cs/ww/en/view/109765109/ - BehobenSIMOCODE pro V PROFINET (incl. SIPLUS variants)siemens_psirt
Update to V2.1.1
https://support.industry.siemens.com/cs/ww/en/view/109749989 - BehobenSIMOTION Csiemens_psirt
Update to V5.1 HF1
https://support.industry.siemens.com/cs/ww/en/view/31263919 - BehobenSIMOTION Dsiemens_psirt
Update to V5.1 HF1
https://support.industry.siemens.com/cs/ww/en/view/31045047 - BehobenSIMOTION P V4.4 and V4.5siemens_psirt
Update to V4.5 HF5 Please contact your Siemens representative for information on how to obtain the update.
- BehobenSIMOTION P V5siemens_psirt
Update to V5.1 HF1 Please contact your Siemens representative for information on how to obtain the update.
- BehobenSINAMICS DCM w. PNsiemens_psirt
Update to V1.4 SP1 HF6
https://support.industry.siemens.com/cs/ww/en/view/44029688 - BehobenSINAMICS DCP w. PNsiemens_psirt
Update to V1.2 HF2
https://support.industry.siemens.com/cs/ww/en/view/109474935 - BehobenSINAMICS G110M w. PNsiemens_psirt
Update to V4.7 SP9 HF1
https://support.industry.siemens.com/cs/document/109750507 - BehobenSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)siemens_psirt
Update to V4.7 SP9 HF1
https://support.industry.siemens.com/cs/document/109750507 - BehobenSINAMICS G130 V4.7 w. PNsiemens_psirt
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS G130 V4.8 w. PNsiemens_psirt
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS G150 V4.7 w. PNsiemens_psirt
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS G150 V4.8 w. PNsiemens_psirt
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS S110 w. PNsiemens_psirt
Update to V4.4 SP3 HF6
https://support.industry.siemens.com/cs/document/109474320 - BehobenSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)siemens_psirt
Update to latest version of V5.1 SP1
https://support.industry.siemens.com/cs/document/109758423 - BehobenSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)siemens_psirt
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/92522512 - BehobenSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)siemens_psirt
Update to V4.8 HF5
https://support.industry.siemens.com/cs/us/en/view/109740193 - BehobenSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)siemens_psirt
Update to latest version of V5.1 SP1
https://support.industry.siemens.com/cs/document/109758423 - BehobenSINAMICS S150 V4.7 w. PNsiemens_psirt
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS S150 V4.8 w. PNsiemens_psirt
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS V90 w. PNsiemens_psirt
Update to V1.02
https://support.industry.siemens.com/cs/document/109746210 - BehobenSINUMERIK 840D slsiemens_psirt
Update to V4.8 SP3 The update can be obtained from your local service organization.
- BehobenSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN ST (6AG1155-5AA00-7AB0)siemens_psirt
Update to V4.1.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN ST TX RAIL (6AG2155-5AA00-4AB0)siemens_psirt
Update to V4.1.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)siemens_psirt
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)siemens_psirt
Update to V4.2.0 or later version
- BehobenDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controllercisa_csaf_ot
Update to V4.1.1 Patch 05
https://support.industry.siemens.com/cs/ww/en/view/109755160 - BehobenDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200cisa_csaf_ot
Update to V4.5
https://support.industry.siemens.com/cs/ww/en/view/109755151 - BehobenDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200Pcisa_csaf_ot
Update to V4.5
https://support.industry.siemens.com/cs/ww/en/view/109750012 - BehobenSIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)cisa_csaf_ot
Update to V1.0.2 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN BA (6ES7155-5AA00-0AA0)cisa_csaf_ot
Update to V4.0.2 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIMATIC ET 200MP IM 155-5 PN ST (6ES7155-5AA00-0AB0)cisa_csaf_ot
Update to V4.1.0 or later version
- BehobenSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)cisa_csaf_ot
Update to V1.1.0
https://support.industry.siemens.com/cs/ww/en/view/109763483 - BehobenSIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIMATIC ET 200SP IM 155-6 PN HS (6ES7155-6AU00-0DN0)cisa_csaf_ot
Update to V4.0.1 or later version
- BehobenSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)cisa_csaf_ot
Update to V4.2.0
https://support.industry.siemens.com/cs/ww/en/view/109760973 - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.2.3
https://support.industry.siemens.com/cs/us/en/view/109741461 - BehobenSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Upgrade to V2.0 or newer
https://support.industry.siemens.com/cs/us/en/ps/13717/dl - BehobenSIMATIC S7-1500 Software Controllercisa_csaf_ot
Upgrade to V2.0 or newer
https://support.industry.siemens.com/cs/us/en/view/109478528 - BehobenSIMATIC S7-200 SMARTcisa_csaf_ot
Update to V2.03.01
https://support.industry.siemens.com/cs/cn/en/view/109749409 - BehobenSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Update to V3.X.16 or later version
https://support.industry.siemens.com/cs/ww/en/ps/13752/dl - BehobenSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V6.0.8 or later version
- BehobenSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V6.0.6 or later version
- BehobenSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V7.0.2 or later version
- BehobenSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V8.2.1
https://support.industry.siemens.com/cs/ww/en/view/109476571 - BehobenSIMATIC TDC CP51M1cisa_csaf_ot
Update to V1.1.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/27049282/ - BehobenSIMATIC TDC CPU555cisa_csaf_ot
Update to V1.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109740119/ - BehobenSIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)cisa_csaf_ot
Update to V2010 SP3 or later version and apply BIOS and Microsoft Windows updates
https://support.industry.siemens.com/cs/ww/en/view/109765109/ - BehobenSIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)cisa_csaf_ot
Update to V2010 SP3 or later version and apply BIOS and Microsoft Windows updates
https://support.industry.siemens.com/cs/ww/en/view/109765109/ - BehobenSIMOCODE pro V PROFINET (incl. SIPLUS variants)cisa_csaf_ot
Update to V2.1.1
https://support.industry.siemens.com/cs/ww/en/view/109749989 - BehobenSIMOTION Ccisa_csaf_ot
Update to V5.1 HF1
https://support.industry.siemens.com/cs/ww/en/view/31263919 - BehobenSIMOTION Dcisa_csaf_ot
Update to V5.1 HF1
https://support.industry.siemens.com/cs/ww/en/view/31045047 - BehobenSIMOTION P V4.4 and V4.5cisa_csaf_ot
Update to V4.5 HF5 Please contact your Siemens representative for information on how to obtain the update.
- BehobenSIMOTION P V5cisa_csaf_ot
Update to V5.1 HF1 Please contact your Siemens representative for information on how to obtain the update.
- BehobenSINAMICS DCM w. PNcisa_csaf_ot
Update to V1.4 SP1 HF6
https://support.industry.siemens.com/cs/ww/en/view/44029688 - BehobenSINAMICS DCP w. PNcisa_csaf_ot
Update to V1.2 HF2
https://support.industry.siemens.com/cs/ww/en/view/109474935 - BehobenSINAMICS G110M w. PNcisa_csaf_ot
Update to V4.7 SP9 HF1
https://support.industry.siemens.com/cs/document/109750507 - BehobenSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.7 SP9 HF1
https://support.industry.siemens.com/cs/document/109750507 - BehobenSINAMICS G130 V4.7 w. PNcisa_csaf_ot
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS G130 V4.8 w. PNcisa_csaf_ot
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS G150 V4.7 w. PNcisa_csaf_ot
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS G150 V4.8 w. PNcisa_csaf_ot
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS S110 w. PNcisa_csaf_ot
Update to V4.4 SP3 HF6
https://support.industry.siemens.com/cs/document/109474320 - BehobenSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Update to latest version of V5.1 SP1
https://support.industry.siemens.com/cs/document/109758423 - BehobenSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/92522512 - BehobenSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.8 HF5
https://support.industry.siemens.com/cs/us/en/view/109740193 - BehobenSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Update to latest version of V5.1 SP1
https://support.industry.siemens.com/cs/document/109758423 - BehobenSINAMICS S150 V4.7 w. PNcisa_csaf_ot
Update to V4.7 HF29
https://support.industry.siemens.com/cs/ww/en/view/103433117 - BehobenSINAMICS S150 V4.8 w. PNcisa_csaf_ot
Update to V4.8 HF4
https://support.industry.siemens.com/cs/ww/en/view/109742040 - BehobenSINAMICS V90 w. PNcisa_csaf_ot
Update to V1.02
https://support.industry.siemens.com/cs/document/109746210 - BehobenSINUMERIK 840D slcisa_csaf_ot
Update to V4.8 SP3 The update can be obtained from your local service organization.
- BehobenSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN ST (6AG1155-5AA00-7AB0)cisa_csaf_ot
Update to V4.1.0 or later version
- BehobenSIPLUS ET 200MP IM 155-5 PN ST TX RAIL (6AG2155-5AA00-4AB0)cisa_csaf_ot
Update to V4.1.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)cisa_csaf_ot
Update to V4.2.0 or later version
- BehobenSIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.4 HF26 The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS GH150 V4.7 w. PROFINETcisa_csaf_ot
Update to V4.7 SP5 HF7 or upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS GL150 V4.7 w. PROFINETcisa_csaf_ot
Upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS GM150 V4.7 w. PROFINETcisa_csaf_ot
Update to V4.7 HF31 or update to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS SL150 V4.7.0 w. PROFINETcisa_csaf_ot
Update to V4.7 HF30 or upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS SL150 V4.7.4 w. PROFINETcisa_csaf_ot
Upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS SL150 V4.7.5 w. PROFINETcisa_csaf_ot
Upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSINAMICS SM120 V4.7 w. PROFINETcisa_csaf_ot
Upgrade to V4.8 SP2. The update can be obtained from your Siemens representative or via Siemens customer service.
- BehobenSIMOCODE pro V EIP (incl. SIPLUS variants)cisa_csaf_ot
Update to V1.0.2 https://support.industry.siemens.com/cs/ww/en/view/1097569122
- MitigationDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controllersiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200Psiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC Compact Field Unitsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200M (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN BA (6ES7155-5AA00-0AA0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN ST (6ES7155-5AA00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN BA (6ES7155-6AR00-0AN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HS (6ES7155-6AU00-0DN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU00-0BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU01-0BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA00-0BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA01-0BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200pro IM 154-3 PN HF (6ES7154-3AB00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200pro IM 154-4 PN HF (6ES7154-4AB10-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200S (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1500 Software Controllersiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-200 SMARTsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC TDC CP51M1siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC TDC CPU555siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOCODE pro V PROFINET (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION Csiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION Dsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION P V4.4 and V4.5siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION P V5siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS DCM w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS DCP w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G110M w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G130 V4.7 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G130 V4.8 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G150 V4.7 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G150 V4.8 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S110 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S150 V4.7 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S150 V4.8 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS V90 w. PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINUMERIK 840D slsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN ST (6AG1155-5AA00-7AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN ST TX RAIL (6AG2155-5AA00-4AB0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU00-7BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU01-7BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA00-7BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA01-7BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA00-4BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA01-4BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU00-4BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU01-4BN0)siemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIRIUS Soft Starter 3RW44 PNsiemens_psirt
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controllercisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200Pcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC Compact Field Unitcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200M (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN BA (6ES7155-5AA00-0AA0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200MP IM 155-5 PN ST (6ES7155-5AA00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN BA (6ES7155-6AR00-0AN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN HS (6ES7155-6AU00-0DN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU00-0BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU01-0BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA00-0BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA01-0BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200pro IM 154-3 PN HF (6ES7154-3AB00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET 200pro IM 154-4 PN HF (6ES7154-4AB10-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200S (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-1500 Software Controllercisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-200 SMARTcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC TDC CP51M1cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC TDC CPU555cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOCODE pro V PROFINET (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION Ccisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION Dcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION P V4.4 and V4.5cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION P V5cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS DCM w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS DCP w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G110M w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G130 V4.7 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G130 V4.8 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G150 V4.7 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS G150 V4.8 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S110 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S150 V4.7 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS S150 V4.8 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINAMICS V90 w. PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSINUMERIK 840D slcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN ST (6AG1155-5AA00-7AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200MP IM 155-5 PN ST TX RAIL (6AG2155-5AA00-4AB0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU00-7BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU01-7BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA00-7BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA01-7BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA00-4BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA01-4BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU00-4BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU01-4BN0)cisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIRIUS Soft Starter 3RW44 PNcisa_csaf_ot
Disable SNMP if this is supported by the product (refer to the product documentation). Disabling SNMP fully mitigates the vulnerability.
- MitigationSIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)cisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS GH150 V4.7 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS GL150 V4.7 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS GM150 V4.7 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS SL150 V4.7.0 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS SL150 V4.7.4 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS SL150 V4.7.5 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSINAMICS SM120 V4.7 w. PROFINETcisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- MitigationSIMOCODE pro V EIP (incl. SIPLUS variants)cisa_csaf_ot
Apply cell protection concept and implement Defense-in-Depth: https://www.siemens.com/cert/operational-guidelines-industrial-security.
- Kein Fix verfügbarSIMATIC Compact Field Unitsiemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter 3RW44 PNsiemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC Compact Field Unitcisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter 3RW44 PNcisa_csaf_ot
Currently no fix is available
- Kein Fix geplantSIMATIC ET 200M (incl. SIPLUS variants)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN BA (6ES7155-6AR00-0AN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU00-0BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU01-0BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA00-0BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA01-0BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200pro IM 154-3 PN HF (6ES7154-3AB00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200pro IM 154-4 PN HF (6ES7154-4AB10-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200S (incl. SIPLUS variants)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU00-7BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU01-7BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA00-7BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA01-7BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA00-4BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA01-4BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU00-4BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU01-4BN0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200M (incl. SIPLUS variants)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN BA (6ES7155-6AR00-0AN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU00-0BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST (6ES7155-6AU01-0BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA00-0BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP IM 155-6 PN ST BA (6ES7155-6AA01-0BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200pro IM 154-3 PN HF (6ES7154-3AB00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200pro IM 154-4 PN HF (6ES7154-4AB10-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200S (incl. SIPLUS variants)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU00-7BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST (6AG1155-6AU01-7BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA00-7BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA (6AG1155-6AA01-7BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA00-4BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL (6AG2155-6AA01-4BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU00-4BN0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP IM 155-6 PN ST TX RAIL (6AG2155-6AU01-4BN0)cisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.6–8.7
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (441)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-346262SSA-346262: Denial of Service Vulnerability in SNMP Interface of Industrial Products2017-11-23csaf · siemens_psirtDE
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-17-339-01Siemens Industrial Products (Update S)2017-11-23icsa · cisa_csaf_otUS
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-18-128-01Siemens Medium Voltage SINAMICS Products (Update A)2018-05-03icsa · cisa_csaf_otUS
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
- ICSA-19-099-01Siemens SIMOCODE pro V EIP2019-04-09icsa · cisa_csaf_otUS
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (29)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.siemens.com/cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-141614.htmlcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-346262.htmlcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-546832.htmlcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdfcnnvd
- https://cert-portal.siemens.com/productcert/txt/ssa-546832.txtcnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan