CVE-2026-58115
criticalpriority · track · 0OT risk · elevatedEPSS 0.010 · 61 %ileDEEUNLUSEPSS · scored 2026-10-27
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)siemens_psirt
Update to V4.3.4.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109741799/ - FixedSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)cisa_csaf_ot
Update to V4.3.4.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109741799/ - MitigationSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)siemens_psirt
Harden the Node-RED installation (see Node-RED User Guide)
- MitigationSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)cisa_csaf_ot
Harden the Node-RED installation (see Node-RED User Guide)
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (24)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2026-0282Kwetsbaarheden verholpen in Siemens productenNL2026-08-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Desigo, Parasolid, RUGGEDCOM, SIMATIC, Siveillance en Solid Edge.
- SSA-834709SSA-834709: Missing Authentication Vulnerability in Node-RED on SIMATIC IoT2050 Advanced with Industrial OS2026-08-11csaf · siemens_psirtDE
SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version.
- ICSA-26-237-03Siemens SIMATIC IoT2050 Advanced2026-08-11icsa · cisa_csaf_otUS
SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version.