CVE-2026-54269
mediumpriority · track · 0EPSS 0.004 · 34 %ileDEEUUSEPSS · scored 2026-10-27
protobufjs compiles protobuf definitions into JavaScript (JS) functions. Prior to 8.6.0 and 7.6.3, protobufjs accepted certain schema-derived names that could collide with properties used by protobufjs runtime helpers. The known affected names are fields named hasOwnProperty, field or oneof names such as $type when loaded through protobufjs JSON/reflection descriptors, and service methods whose generated helper name is rpcCall. When affected message or service types were used, protobufjs could read schema-controlled data where it expected an own-property helper, reflected type metadata, or the base RPC helper. This could cause deterministic exceptions or recursive calls in affected decode post-checks, verification, object conversion, reflected JSON serialization, or protobufjs RPC helper invocation. This vulnerability is fixed in 8.6.0 and 7.6.3.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (15)
Products and version ranges known to be affected.
- protobufjs project protobufjs8.0.0 → 8.6.0nvdUScpe:2.3:a:protobufjs_project:protobufjs:*:*:*:*:*:*:*:*
- protobufjs project protobufjs-cli< 1.3.3nvdUScpe:2.3:a:protobufjs_project:protobufjs-cli:*:*:*:*:*:*:*:*
- protobufjs project protobufjs-cli2.0.0 → 2.5.1nvdUScpe:2.3:a:protobufjs_project:protobufjs-cli:*:*:*:*:*:*:*:*
advisories (2)
Vendor and ecosystem advisories describing this.
- WID-SEC-W-2026-2488IBM App Connect Enterprise: Mehrere SchwachstellenDeutsch2026-07-22csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in IBM App Connect Enterprise ausnutzen, um einen Denial of Service Angriff durchzuführen, um Informationen offenzulegen, um Dateien zu manipulieren, um einen Cross-Site Scripting Angriff durchzuführen, und um Sicherheitsvorkehrungen zu umgehen.
- GHSA-f38q-mgvj-vph7protobufjs : Schema-derived names can shadow runtime-significant properties2026-06-15ghsa · osvUS
## Summary protobufjs accepted certain schema-derived names that could collide with properties used by protobufjs runtime helpers. The known affected names are fields named `hasOwnProperty`, field or oneof names such as `$type` when loaded through protobufjs JSON/reflection descriptors, and service methods whose generated helper name is `rpcCall`. When affected message or service types were used, protobufjs could read schema-controlled data where it expected an own-property helper, reflected type metadata, or the base RPC helper. This could cause deterministic exceptions or recursive calls in affected decode post-checks, verification, object conversion, reflected JSON serialization, or protobufjs RPC helper invocation. ## Impact An attacker who can provide or influence protobuf schemas or protobufjs JSON descriptors may be able to make affected message or service types unusable, resulting in denial of service for the affected processing path. Applications using only trusted schemas are affected only if those schemas contain one of the problematic names and the application reaches the affected API path. The issue is not known to allow code execution by itself. ## Preconditions * The application must use an affected protobufjs version. * The application must load or use a schema or protobufjs JSON descriptor containing one of the problematic names: * a field named `hasOwnProperty`, * a field or oneof named `$type` through protobufjs JSON/reflection descriptor input, * or a service method whose generated helper name is `rpcCall`. * The application must reach the affected API path for that name: required-field decode post-checks, `verify`, or `toObject` for `hasOwnProperty`; reflected message JSON serialization for `$type`; or protobufjs RPC service invocation for `rpcCall`. ## Workarounds Do not load protobuf schemas or protobufjs JSON descriptors from untrusted sources with affected versions. If untrusted schemas or descriptors must be accepted, validate schema-derived field, oneof, and service method names before loading and reject the problematic names described above. Applications using trusted schemas can avoid the issue by renaming affected fields or service methods, or by avoiding the affected API path.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (3)
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.