CVE-2026-48095

highpriority · track · 10EPSS 0.011 · 66 %ileexploit · PoCDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
1.12% (66th) EPSS
CVSS 8.8 · high
Is it mine?
18 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · bosch_psirt

EPSS · scored 2026-10-27

7-Zip is a file archiver with a high compression ratio. Versions 26.00 and prior contain a heap buffer overflow vulnerability caused by an under-allocation in the NTFS compressed stream buffer (GetCuSize shift UB), potentially allowing attackers to cause arbitrary code execution or application crashes. CInStream::GetCuSize() in the NTFS handler computes the compression-unit buffer size as (UInt32)1 << (BlockSizeLog + CompressionUnit), and a crafted image with ClusterSizeLog >= 28 and CompressionUnit == 4 drives the exponent to 32, which is undefined behavior and collapses on x86/x64 so _inBuf is allocated as 1 byte. ReadStream_FALSE then writes up to 256 MB of attacker-controlled data into that 1-byte buffer in 64 KB iterations, and because the CInStream object sits only 304 bytes after _inBuf, its vtable pointer is overwritten and the next dispatched call achieves a vtable hijack. On 32-bit builds the overflow is unconditionally reached; on 64-bit it requires the parallel 8 GB _outBuf allocation to succeed, otherwise failing closed to denial of service. The NTFS handler is enabled by default in stock 7z.dll and, via signature-based fallback matching "NTFS " at offset 3, will open a crafted image regardless of file extension during extraction or testing. Version 26.01 fixes the issue.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedBosch Rexroth AG PRI7000bosch_psirt

    Update to PRI7000 version 1.11.18.2 or newer, if possible.

  • MitigationBosch Rexroth AG PRI7000bosch_psirt

    Navigate to the "Simulator" Folder typically installed on drive (C:)Windows - ProgramData - Bosch Rexroth AG - PRI7000_Data - V.1.11.XX.X - Common - Simulator In the Simulator folder you can choose three different releases of the PRI7000. The actual one and the two versions before. For each Version please navigate into the "7zip" folder V1.11.XX.X - App - Tools - 7zip Please delete the Folder "Far" in each of the three versions The vulnerable source code is deleted from the computer and can not affect the installed PRI7000 versions

02

cvss

Technical severity, 0–10. One row per scoring source.

8.8
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.18.8highAV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · security-advisories@github.comexploitability 2.8 · impact 5.9
v3.18.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Psecondary · CVSS-BT (t0sche)
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Bosch PSIRT DE
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: poc · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

exploits (1)

Public proof-of-concept and weaponised exploit code.

06

affected products (18)

Products and version ranges known to be affected.

07

advisories (2)

Vendor and ecosystem advisories describing this.

08

also known as (3)

Other names and identifiers for this entity.

09

sources

Which sources assert this record, and when.

10

references (7)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan