CVE-2026-41125

mediumpriority · track · 0EPSS 0.002 · 5 %ileDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.15% (5th) EPSS
CVSS 6 · medium
Is it mine?
185 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

6.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2–6

v3.16mediumCVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:Hsecondary · NCSC-NL NL
v3.16mediumAV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.16mediumCVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 0.5 · impact 5.5
v3.16mediumCVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.16mediumCVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:H/A:Hsecondary · CISA US
v4.05.9mediumCVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.05.9mediumCVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.02lowCVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (185)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • NCSC-2026-0147Kwetsbaarheden verholpen in Siemens-productenNL2026-05-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in verschillende (OT-)producten. Het gaat onder andere om producten in de Siemens RUGGEDCOM-, SCALANCE-, SIMATIC-, SIMIT-, SINAMICS-, SIPROTEC-, SENTRON- en Solid Edge-productreeksen.

  • SSA-545643SSA-545643: Multiple Vulnerabilities in KACO Blueplanet Inverters2026-05-12csaf · siemens_psirtDE

    KACO blueplanet Inverters contain multiple vulnerabilities that could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. KACO new energy GmbH has released new versions for several affected products and recommends to update to the latest versions. KACO new energy GmbH is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-26-160-02Siemens KACO Blueplanet Inverters2026-05-12icsa · cisa_csaf_otUS

    KACO blueplanet Inverters contain multiple vulnerabilities that could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. KACO new energy GmbH has released new versions for several affected products and recommends to update to the latest versions. KACO new energy GmbH is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan