CVE-2026-31789

criticalpriority · track · 39EPSS 0.002 · 15 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.24% (15th) EPSS
CVSS 9.8 · critical
Is it mine?
93 products
Check your exposure
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-22

Issue summary: Converting an excessively large OCTET STRING value to a hexadecimal string leads to a heap buffer overflow on 32 bit platforms. Impact summary: A heap buffer overflow may lead to a crash or possibly an attacker controlled code execution or other undefined behavior. If an attacker can supply a crafted X.509 certificate with an excessively large OCTET STRING value in extensions such as the Subject Key Identifier (SKID) or Authority Key Identifier (AKID) which are being converted to hex, the size of the buffer needed for the result is calculated as multiplication of the input length by 3. On 32 bit platforms, this multiplication may overflow resulting in the allocation of a smaller buffer and a heap buffer overflow. Applications and services that print or log contents of untrusted X.509 certificates are vulnerable to this issue. As the certificates would have to have sizes of over 1 Gigabyte, printing or logging such certificates is a fairly unlikely operation and only 32 bit platforms are affected, this issue was assigned Low severity. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the affected code is outside the OpenSSL FIPS module boundary.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 5.8–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.17highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.15.8mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:Hsecondary · ENISA EU
v3.15.8mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:Hsecondaryexploitability 1 · impact 4.7
v3.17highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · Siemens ProductCERT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · NCSC-NL NL
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (93)

Products and version ranges known to be affected.

showing 20 of 93
06

advisories (4)

Vendor and ecosystem advisories describing this.

  • NCSC-2026-0147Kwetsbaarheden verholpen in Siemens-productenNL2026-05-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in verschillende (OT-)producten. Het gaat onder andere om producten in de Siemens RUGGEDCOM-, SCALANCE-, SIMATIC-, SIMIT-, SINAMICS-, SIPROTEC-, SENTRON- en Solid Edge-productreeksen.

  • SSA-032379SSA-032379: Multiple Vulnerabilities in SIMATIC CN 4100 Before V5.02026-05-12csaf · siemens_psirtDE

    SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.

  • WID-SEC-W-2026-0995OpenSSL: Mehrere SchwachstellenDeutsch2026-04-07csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen, vertrauliche Informationen offenzulegen oder andere, nicht näher spezifizierte Angriffe durchzuführen.

  • ICSA-26-134-10Siemens SIMATIC2026-05-12icsa · cisa_csaf_otUS

    SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (22)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan