CVE-2026-25655
highpriority · track · 0EPSS 0.003 · 19 %ileDEEUNLRUUSEPSS · scored 2026-10-27
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP2). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with administrative privilege.(ZDI-CAN-28107)
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSINEC NMSsiemens_psirt
Update to V4.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109998317/ - FixedSINEC NMScisa_csaf_ot
Update to V4.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109998317/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5.9–8.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (48)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2026-0051Kwetsbaarheden verholpen in Siemens productenNL2026-02-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Desigo, NX, Polarion, SENTRON, Simcenter, SINEC, SIPORT, Siveillance, Solid Edge,
- SSA-311973SSA-311973: Multiple Local Privilege Escalation Vulnerabilities in SINEC NMS and User Management Component (UMC)2026-02-10csaf · siemens_psirtDE
Multiple Siemens products are affected by two local privilege escalation vulnerabilities which could allow an low privileged attacker to load malicious DLLs, potentially leading to arbitrary code execution with elevated privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-26-043-01Siemens SINEC NMS2026-02-10icsa · cisa_csaf_otUS
Multiple Siemens products are affected by two local privilege escalation vulnerabilities which could allow an low privileged attacker to load malicious DLLs, potentially leading to arbitrary code execution with elevated privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
also known as (5)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan