CVE-2026-12705

mediumpriority · track · 0EPSS 0.002 · 4 %ileCHEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.15% (4th) EPSS
CVSS 6.4 · medium
Is it mine?
8 products
Check your exposure
Who says so?
4 sources
cnnvd · enisa_euvd · abb_psirt · cisa_csaf_ot

EPSS · scored 2026-10-27

Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE). This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

No vendor fix yet; a mitigation is available.

  • MitigationKNX Update Tool (ABB)abb_psirt

    Due to the nature of the classic KNX protocol stack and security concept, there are no options to resolve the vulnerability with a software update on a technical level. ABB recommends to follow general security recommendations listed in the security guideline (see References and General security recommendations). In addition, it shall be avoided to control sensitive functionality by legacy KNX devices such as, but not limited to, access control to e.g. hotel rooms or other protected areas. Note: Legacy KNX standards were never designed to meet state of the art security standards like introduced with KNX Data Secure published in 2017.

  • MitigationKNX Update Tool (BJE)abb_psirt

    Due to the nature of the classic KNX protocol stack and security concept, there are no options to resolve the vulnerability with a software update on a technical level. ABB recommends to follow general security recommendations listed in the security guideline (see References and General security recommendations). In addition, it shall be avoided to control sensitive functionality by legacy KNX devices such as, but not limited to, access control to e.g. hotel rooms or other protected areas. Note: Legacy KNX standards were never designed to meet state of the art security standards like introduced with KNX Data Secure published in 2017.

  • MitigationKNX Update Tool (ABB)cisa_csaf_ot

    Due to the nature of the classic KNX protocol stack and security concept, there are no options to resolve the vulnerability with a software update on a technical level. ABB recommends to follow general security recommendations listed in the security guideline (see References and General security recommendations). In addition, it shall be avoided to control sensitive functionality by legacy KNX devices such as, but not limited to, access control to e.g. hotel rooms or other protected areas. Note: Legacy KNX standards were never designed to meet state of the art security standards like introduced with KNX Data Secure published in 2017.

  • MitigationKNX Update Tool (BJE)cisa_csaf_ot

    Due to the nature of the classic KNX protocol stack and security concept, there are no options to resolve the vulnerability with a software update on a technical level. ABB recommends to follow general security recommendations listed in the security guideline (see References and General security recommendations). In addition, it shall be avoided to control sensitive functionality by legacy KNX devices such as, but not limited to, access control to e.g. hotel rooms or other protected areas. Note: Legacy KNX standards were never designed to meet state of the art security standards like introduced with KNX Data Secure published in 2017.

02

cvss

Technical severity, 0–10. One row per scoring source.

6.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2.2–6.4

v3.16.4mediumCVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:F/RL:U/RC:Csecondary · CISA US
v3.16.4mediumCVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:Hsecondary · cybersecurity@ch.abb.comexploitability 1.2 · impact 5.2
v3.16.4mediumCVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H/E:F/RL:U/RC:Csecondary · ABB PSIRT
v4.05.9mediumCVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.05.9mediumCVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@ch.abb.com
v4.02.2lowCVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (8)

Products and version ranges known to be affected.

06

advisories (2)

Vendor and ecosystem advisories describing this.

  • 9AKK108472A9270ABB/EL/ELSB/Building Automation File integrity can be bypassed in KNX Update Tool for classic KNX products2026-07-17csaf · abb_psirtCH

    ABB has been contacted by a researcher who identified a vulnerability in one of its products. ABB has been contacted by a researcher who identified a vulnerability in one of its products. The vulnerability report has been shared in responsible disclosure. An attacker who successfully exploited this vulnerability could cause the product to become unusable. ABB confirms the vulnerability but at the same time acknowledges that the issue affects exclusively classic KNX devices that are not supporting the latest KNX Secure standard. Due to a lack of security in legacy KNX devices, the issue cannot be resolved via a software change. In order to actively exploit this vulnerability, an attacker requires physical access to the bus, the affected device is connected to. ABB has no plans of corrective measures.

  • ICSA-26-209-07ABB KNX Update Tool2026-07-17icsa · cisa_csaf_otUS

    ABB has been contacted by a researcher who identified a vulnerability in one of its products. ABB has been contacted by a researcher who identified a vulnerability in one of its products. The vulnerability report has been shared in responsible disclosure. An attacker who successfully exploited this vulnerability could cause the product to become unusable. ABB confirms the vulnerability but at the same time acknowledges that the issue affects exclusively classic KNX devices that are not supporting the latest KNX Secure standard. Due to a lack of security in legacy KNX devices, the issue cannot be resolved via a software change. In order to actively exploit this vulnerability, an attacker requires physical access to the bus, the affected device is connected to. ABB has no plans of corrective measures.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (3)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan