CVE-2025-7376
mediumpriority · track · 0EPSS 0.002 · 12 %ileEURUUSEPSS · scored 2026-10-27
Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedAnalytiXcisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedAnalytiXcisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedGENESIScisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 11.01 or later for GENESIS. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedGENESIScisa_csaf_ot
Mitsubishi Electric is releasing fixed version 11.01 or later for GENESIS. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedGENESIS64cisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedGENESIS64cisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedHyper Historiancisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedHyper Historiancisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedICONICS Suitecisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedICONICS Suitecisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedIoTWorXcisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.96 or later for IoTWorX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/a375a000004qDU8AAM/iotworx" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedIoTWorXcisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.96 or later for IoTWorX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/a375a000004qDU8AAM/iotworx" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - FixedMobileHMIcisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities which can be found at "https://iconics.com/about/security/cert".
https://iconics.com/about/security/cert - FixedMobileHMIcisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, and AnalytiX. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads?tabset-a9d51=51905" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf - MitigationAnalytiXcisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationGENESIScisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationGENESIS64cisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationHyper Historiancisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationICONICS Suitecisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationIoTWorXcisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationMC Works 64cisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- MitigationMobileHMIcisa_csaf_ot
For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend blocking unauthorized access by using a firewall, virtual private network (VPN), etc. and allowing remote login only to administrator when connecting the PCs with the affected product installed to the Internet, to minimize the risk of exploiting this vulnerability.
- No fix plannedMC Works 64cisa_csaf_ot
There are no plans to release fixed version for MC Works64.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (41)
Products and version ranges known to be affected.
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-25-217-01Mitsubishi Electric Iconics Digital Solutions Multiple Products (Update B)2025-08-05icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could allow a local attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.
also known as (5)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (9)
External citations — patches, advisories, analysis.
- https://jvn.jp/vu/JVNVU96364629cnnvd
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01cnnvd
- https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdfcnnvd
- https://jvn.jp/vu/JVNVU96364629enisa_euvd
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01enisa_euvd
- https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdfenisa_euvd
- https://jvn.jp/vu/JVNVU96364629nvd
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01nvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.