CVE-2025-55093

mediumpriority · track · 21EPSS 0.003 · 24 %ileDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.31% (24th) EPSS
CVSS 5.3 · medium
Is it mine?
6 products
Check your exposure
Who says so?
4 sources
cnnvd · enisa_euvd · nvd · sick_psirt

EPSS · scored 2026-10-27

In NetX Duo before 6.4.4, the networking support module for Eclipse Foundation ThreadX, there was a potential out of bound read issue in _nx_ipv4_packet_receive() when handling unicast DHCP messages that could cause corruption of 4 bytes of memory.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

No vendor fix yet; a mitigation is available.

  • MitigationSICK microScan3 EtherCAT all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK microScan3 Pro I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK nanoScan3 Core I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK nanoScan3 Pro I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

02

cvss

Technical severity, 0–10. One row per scoring source.

6.9
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2.7–6.9

v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:Nprimary · NVD / NIST USexploitability 3.9 · impact 1.4
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:Nsecondary · SICK PSIRT DE
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · emo@eclipse.org
v4.02.7lowCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (6)

Products and version ranges known to be affected.

06

advisories (1)

Vendor and ecosystem advisories describing this.

  • SCA-2026-0003Vulnerability affecting SICK nanoScan3 and microScan32026-01-26csaf · sick_psirtDE

    SICK has identified a 3rd party vulnerability (CVE-2025-55093) in the nanoScan3 and microScan3. Only specific variants within the microScan3 and nanoScan3 families are affected by CVE-2025-55093. The underlying issue in the NetX Duo networking module could, under specific conditions, cause the device to enter a safe error state that requires a restart. SICK recommends applying the mitigation for CVE-2025-55093.

07

also known as (2)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

published 2025-10-17modified 2026-06-17
10

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan