A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a console and through exploitation of a setup script.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedEcoStruxure™ IT Data Center Expertcisa_csaf_ot

    Version 9.0 of EcoStruxure™ IT Data Center Expert includes fixes for these vulnerabilities and is available upon request from Schneider Electric’s Customer Care Center.

  • MitigationEcoStruxure™ IT Data Center Expertcisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Harden the DCE instance according to the cybersecurity best practices documented in the EcoStruxure™ IT Data Center Expert Security Handbook

    https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553
02

cvss

Technical severity, 0–10. One row per scoring source.

7.2
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–high · 3.9–7.2

v3.16.9mediumCVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.16.9mediumCVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · NCSC-NL NL
v4.07.2highCVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:Hsecondary · ENISA EU
v4.07.2highCVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@se.com
v4.03.9lowCVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (6)

Products and version ranges known to be affected.

06

advisories (2)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0221Kwetsbaarheden verholpen in Schneider Electric EcoStruxture IT Datacenter ExpertNL2025-07-09csaf · ncsc_nlNL

    Schneider Electric heeft kwetsbaarheden verholpen in EcoStruxture IT Datacenter Expert.

  • ICSA-25-203-06Schneider Electric EcoStruxture IT Data Center Expert2025-07-08icsa · cisa_csaf_otUS

    Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ IT Data Center Expert (DCE) product. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure, and remote compromise of the offer which could result in disruption of operations and access to system data.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

published 2025-07-11modified 2026-06-17
09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan