CVE-2025-40936

highpriority · track · 0EPSS 0.002 · 10 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.20% (10th) EPSS
CVSS 7.8 · high
Is it mine?
50 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-22

A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Simcenter Femap (All versions < V2512.0003), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.4–7.8

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · NCSC-NL NL
v3.17.8highAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 1.8 · impact 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.04.4mediumCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (50)

Products and version ranges known to be affected.

06

advisories (6)

Vendor and ecosystem advisories describing this.

  • NCSC-2026-0051Kwetsbaarheden verholpen in Siemens productenNL2026-02-10csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Desigo, NX, Polarion, SENTRON, Simcenter, SINEC, SIPORT, Siveillance, Solid Edge,

  • SSA-241605SSA-241605: Out of Bounds Read in PS/IGES Parasolid Translator Component Before V29.0.2582025-11-17csaf · siemens_psirtDE

    PS/IGES Parasolid Translator Component contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for PS/IGES Parasolid Translator Component and recommends to update to the latest version.

  • SSA-445819SSA-445819: Out of Bounds Read in PS/IGES Parasolid Translator Component in Solid Edge2026-02-10csaf · siemens_psirtDE

    Solid Edge uses PS/IGES Parasolid Translator Component that contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Solid Edge and recommends to update to the latest version.

  • SSA-870926SSA-870926: Datakit and Parasolid Vulnerabilities in Simcenter Femap2026-05-12csaf · siemens_psirtDE

    Simcenter Femap is affected by file parsing vulnerabilities in Datakit library and Parasolid Translator Component that could be triggered when the application reads files in IPT or IGS format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

  • ICSA-26-043-05Siemens Solid Edge2026-02-10icsa · cisa_csaf_otUS

    Solid Edge uses PS/IGES Parasolid Translator Component that contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Solid Edge and recommends to update to the latest version.

  • ICSA-26-134-05Siemens Simcenter Femap2026-05-12icsa · cisa_csaf_otUS

    Simcenter Femap is affected by file parsing vulnerabilities in Datakit library and Parasolid Translator Component that could be triggered when the application reads files in IPT or IGS format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

07

also known as (6)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (9)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan