CVE-2025-40818

lowpriority · track · 0EPSS 0.001 · 1 %ileDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.10% (1st) EPSS
CVSS 3.3 · low
Is it mine?
39 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-22

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

3.3
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.13.3lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · CISA US
v3.13.3lowAV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.13.3lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · ENISA EU
v3.13.3lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · productcert@siemens.com DEexploitability 1.8 · impact 1.4
v3.13.3lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · Siemens ProductCERT DE
v3.13.1lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
v3.13.3lowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:Nsecondary · NCSC-NL NL
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (39)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0382Kwetsbaarheden verholpen in Siemens productenNL2025-12-09csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Building X, COMOS, Energy Services, Gridscale X, NX, RUGGEDCOM, SICAM, SIMATIC, SINEC, SINEMA, SIPLUS en Solid Edge.

  • SSA-626856SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP42025-12-09csaf · siemens_psirtDE

    SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.

  • ICSA-25-345-06Siemens SINEMA Remote Connect Server2025-12-09icsa · cisa_csaf_otUS

    SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (3)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan