CVE-2025-40765
criticalpriority · track · 0OT risk · elevatedEPSS 0.005 · 45 %ileDEEUNLUSEPSS · scored 2026-10-27
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affected application contains an information disclosure vulnerability. This could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedTeleControl Server Basic V3.1siemens_psirt
Update to V3.1.2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109995705/ - FixedTeleControl Server Basic V3.1cisa_csaf_ot
Update to V3.1.2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109995705/ - MitigationTeleControl Server Basic V3.1siemens_psirt
Restrict access to port 8000 on the affected systems to trusted IP addresses only
- MitigationTeleControl Server Basic V3.1cisa_csaf_ot
Restrict access to port 8000 on the affected systems to trusted IP addresses only
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 8.1–9.8
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (16)
Products and version ranges known to be affected.
- siemens telecontrol server basic= 3.1.2.2nvdUScpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2025-0309Kwetsbaarheden verholpen in Siemens productenNL2025-10-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als SIMATIC, SINEC, SIPLUS en Solid Edge.
- SSA-062309SSA-062309: Information Disclosure Vulnerability in TeleControl Server Basic V3.12025-10-14csaf · siemens_psirtDE
TeleControl Server Basic V3.1 contains an information disclosure vulnerability that could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service. Siemens has released a new version for TeleControl Server Basic V3.1 and recommends to update to the latest version.
- ICSA-25-289-09Siemens TeleControl Server Basic2025-10-14icsa · cisa_csaf_otUS
TeleControl Server Basic V3.1 contains an information disclosure vulnerability that could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service. Siemens has released a new version for TeleControl Server Basic V3.1 and recommends to update to the latest version.