CVE-2025-40594

criticalpriority · track · 39EPSS 0.002 · 10 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.21% (10th) EPSS
CVSS 9.8 · critical
Is it mine?
29 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-24

A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–critical · 3.4–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.16.3mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:Lsecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.16.3mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:Lsecondary · NCSC-NL NL
v3.16.3mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:Lsecondary · productcert@siemens.com DEexploitability 1 · impact 4.7
v3.16.3mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:Lsecondary · Siemens ProductCERT DE
v4.06.9mediumCVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:Lsecondary · ENISA EU
v4.06.9mediumCVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.03.4lowCVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (29)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0274Kwetsbaarheden verholpen in Siemens productenNL2025-09-09csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, Industial Edge, RUGGEDCOM, SIMATIC, SIMOTION en SINAMICS.

  • SSA-027652SSA-027652: Privilege Escalation Vulnerability in SINAMICS Drives2025-09-09csaf · siemens_psirtDE

    Siemens SINAMICS G220, SINAMICS S210, and SINAMICS S200 contains a privilege escalation vulnerability that could allow users to escalate their privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-254-03Siemens SINAMICS Drives2025-09-09icsa · cisa_csaf_otUS

    Siemens SINAMICS G220, SINAMICS S210, and SINAMICS S200 contains a privilege escalation vulnerability that could allow users to escalate their privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan