CVE-2025-40570

lowpriority · track · 0EPSS 0.002 · 9 %ileDEEUNLUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.20% (9th) EPSS
CVSS 2.4 · low
Is it mine?
237 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · cert_bund · cisa_csaf_ot

EPSS · scored 2026-10-26

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

2.4
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.12.4lowCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lsecondary · productcert@siemens.com DEexploitability 0.9 · impact 1.4
v3.12.4lowCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lsecondary · CISA US
v3.12.4lowCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lsecondary · Siemens ProductCERT DE
v3.12.4lowCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lsecondary · NCSC-NL NL
v4.02.4lowCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.02.4lowCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.00.4lowCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (237)

Products and version ranges known to be affected.

06

advisories (4)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0246Kwetsbaarheden verholpen in Siemens productenNL2025-08-12csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als SIMATIC, SINEC, SIMAC, RUGGEDCOM, SIMOTION, SINAMICS, SIPROTEC en SINUMERIK.

  • SSA-894058SSA-894058: Improper Bandwidth Limitation of Network Packets Over Local USB Port Vulnerability in SIPROTEC 52025-08-12csaf · siemens_psirtDE

    Affected SIPROTEC 5 devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack and the protection function is not affected of this vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2025-1768Siemens SIPROTEC: Mehrere Schwachstellen ermöglichen Denial of ServiceDeutsch2025-08-12csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer oder ein Angreifer mit physischem Zugriff kann mehrere Schwachstellen in Siemens SIPROTEC ausnutzen, um einen Denial of Service Angriff durchzuführen.

  • ICSA-25-226-10Siemens SIPROTEC 52025-08-12icsa · cisa_csaf_otUS

    Affected SIPROTEC 5 devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack and the protection function is not affected of this vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (3)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan