CVE-2025-27769
lowpriority · track · 0EPSS 0.001 · 4 %ileDEEUNLUSEPSS · scored 2026-10-23
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedHeliox Flex 180 kW EV Charging Stationsiemens_psirt
Contact customer support for patch information via OTA update
- FixedHeliox Mobile DC 40 kW EV Charging Stationsiemens_psirt
Contact customer support for patch information via OTA update
- FixedHeliox Flex 180 kW EV Charging Stationcisa_csaf_ot
Contact customer support for patch information via OTA update
- FixedHeliox Mobile DC 40 kW EV Charging Stationcisa_csaf_ot
Contact customer support for patch information via OTA update
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (134)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2026-0079Kwetsbaarheden verholpen in Siemens productenNL2026-03-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Heliox, Ruggedcom, SICAM, SIDIS en SIMATIC.
- SSA-126399SSA-126399: Improper Access Control Vulnerability in Heliox EV Chargers2026-03-10csaf · siemens_psirtDE
Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-26-071-05Siemens Heliox EV Chargers2026-03-10icsa · cisa_csaf_otUS
Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions.