CVE-2025-27493

mediumpriority · track · 27EPSS 0.002 · 7 %ileDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.18% (7th) EPSS
CVSS 6.7 · medium
Is it mine?
119 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-22

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSiPass integrated AC5102 (ACC-G2)siemens_psirt

    Update to V6.4.9 or later version

  • FixedSiPass integrated ACC-APsiemens_psirt

    Update to V6.4.9 or later version

  • FixedSiPass integrated AC5102 (ACC-G2)cisa_csaf_ot

    Update to V6.4.9 or later version

  • FixedSiPass integrated ACC-APcisa_csaf_ot

    Update to V6.4.9 or later version

  • MitigationSiPass integrated AC5102 (ACC-G2)siemens_psirt

    Set an individual strong password for the administrator account ("SIEMENS")

  • MitigationSiPass integrated ACC-APsiemens_psirt

    Set an individual strong password for the administrator account ("SIEMENS")

  • MitigationSiPass integrated AC5102 (ACC-G2)cisa_csaf_ot

    Set an individual strong password for the administrator account ("SIEMENS")

  • MitigationSiPass integrated ACC-APcisa_csaf_ot

    Set an individual strong password for the administrator account ("SIEMENS")

02

cvss

Technical severity, 0–10. One row per scoring source.

9.3
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 6.7–9.3

v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 0.8 · impact 5.9
v3.18.2highCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.18.2highAV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.18.2highCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · NCSC-NL NL
v3.18.2highCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 1.5 · impact 6
v3.18.2highCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v4.09.3criticalCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:Hsecondary · ENISA EU
v4.09.3criticalCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.3highCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (119)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0077Kwetsbaarheden verholpen in Siemens productenNL2025-03-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als SCALANCE, SIMATIC, SINAMICS, SINEMA, SiPass, Teamcenter en Tecnomatix.

  • SSA-515903SSA-515903: Multiple Vulnerabilities in SiPass integrated AC5102 / ACC-G2 and ACC-AP2025-03-11csaf · siemens_psirtDE

    SiPass integrated ACC (Advanced Central Controller) devices contain multiple vulnerabilities that could allow attackers to execute commands on the devices with root privileges and access sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-072-04Siemens SiPass integrated AC5102/ACC-G2 and ACC-AP2025-03-11icsa · cisa_csaf_otUS

    SiPass integrated ACC (Advanced Central Controller) devices contain multiple vulnerabilities that could allow attackers to execute commands on the devices with root privileges and access sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.