CVE-2025-13902

mediumpriority · track · 22EPSS 0.002 · 15 %ileEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.24% (15th) EPSS
CVSS 5.4 · medium
Is it mine?
16 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedModicon Controller M241 Firmware Versions prior to 5.4.13.12 installed on Modicon Controllers M241cisa_csaf_ot

    Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/ Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/

    https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER
  • FixedModicon Controller M251 Firmware Versions prior to 5.4.13.12 installed on Modicon Controllers M251cisa_csaf_ot

    Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/ Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/

    https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER
  • MitigationModicon Controller M241 Firmware Versions prior to 5.4.13.12 installed on Modicon Controllers M241cisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Deactivate the Webserver after use when not needed. • Use encrypted communication links. • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines.

    https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242
  • MitigationModicon Controller M251 Firmware Versions prior to 5.4.13.12 installed on Modicon Controllers M251cisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Deactivate the Webserver after use when not needed. • Use encrypted communication links. • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines.

    https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242
  • MitigationModicon Controllers LMC058 Firmware All versions installed on Modicon Controllers LMC058cisa_csaf_ot

    • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Deactivate the Webserver after use when not needed. • Use encrypted communication links. • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines.

    https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242
  • MitigationModicon Controllers M258 Firmware All versions installed on Modicon Controllers M258cisa_csaf_ot

    • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. • Deactivate the Webserver after use when not needed. • Use encrypted communication links. • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. • Use VPN (Virtual Private Networks) tunnels if remote access is required. • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines.

    https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242
02

cvss

Technical severity, 0–10. One row per scoring source.

5.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 1.2–5.4

v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USexploitability 2.3 · impact 2.7
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · CISA US
v3.15.4mediumAV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · FSTEC (BDU) RU
v4.05.1mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:Nsecondary · ENISA EU
v4.05.1mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@se.com
v4.01.2lowCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (16)

Products and version ranges known to be affected.

06

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-26-078-02Schneider Electric Modicon Controllers M241, M251, M258, and LMC0582026-03-10icsa · cisa_csaf_otUS

    Schneider Electric is aware of a vulnerability in its Modicon Controllers M241 / M251, M258, and LMC058 products. The [Modicon Controllers M241 / M251 / M258](https://www.se.com/ww/en/product-category/3900-plc-pac-and-dedicated-controllers/) and [Modicon LMC058](https://www.se.com/ww/en/product-range/7744-modicon-lmc058/) are Programmable Logic Controllers for performance-demanding applications. Failure to apply the remediation or mitigations provided below may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser.