CVE-2024-6788

criticalpriority · track · 39OT risk · elevatedEPSS 0.005 · 43 %ileDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.50% (43rd) EPSS
CVSS 9.8 · critical
Is it mine?
20 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · nvd

EPSS · scored 2026-10-27

A remote unauthenticated attacker can use the firmware update feature on the LAN interface of the device to reset the password for the predefined, low-privileged user “user-app” to the default password.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • Fixedphoenix_contact_psirt

    Phoenix Contact strongly recommends upgrading affected charge controllers to firmware version 1.6.3 or higher which fixes these vulnerabilities.

  • Workaroundphoenix_contact_psirt

    Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to General Recommendation.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 8.6–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.18.6highAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · FSTEC (BDU) RU
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · ENISA EU
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · info@cert.vde.comexploitability 3.9 · impact 4.7
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · Phoenix Contact PSIRT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (20)

Products and version ranges known to be affected.

06

advisories (1)

Vendor and ecosystem advisories describing this.

  • VDE-2024-022Phoenix Contact: Security Advisory for CHARX-SEC3xxx Charge controllers2024-08-13csaf · phoenix_contact_psirtDE

    Start sequence for firewall service allows attack during the boot process. Password is reset to default when the device undergoes a firmware upgrade.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (6)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan