CVE-2024-41790

highpriority · track · 29EPSS 0.009 · 60 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.91% (60th) EPSS
CVSS 7.2 · high
Is it mine?
97 products
Check your exposure
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-22

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

The vendor does not plan to fix this; mitigate or replace.

  • No fix plannedSENTRON 7KT PAC1260 Data Managersiemens_psirt

    Currently no fix is planned

  • No fix plannedSENTRON 7KT PAC1260 Data Managercisa_csaf_ot

    Currently no fix is planned

02

cvss

Technical severity, 0–10. One row per scoring source.

9.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.2–9.4

v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 1.2 · impact 5.9
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.19.1criticalAV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · NCSC-NL NL
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 2.3 · impact 6
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v4.09.4criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:Hsecondary · ENISA EU
v4.09.4criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.6highCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (97)

Products and version ranges known to be affected.

06

advisories (4)

Vendor and ecosystem advisories describing this.

  • NCSC-2025-0106Kwetsbaarheden verholpen in Siemens productenNL2025-04-08csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Industrial Edge Devices, Mendix, SENTRON, SIDIS, SIMATIC, SIPLUS,Insights Hub Private Cloud, Siemens License Server en Solid Edge.

  • SSA-187636SSA-187636: Multiple Vulnerabilities in SENTRON 7KT PAC1260 Data Manager2025-04-08csaf · siemens_psirtDE

    SENTRON 7KT PAC1260 Data Manager is affected by multiple vulnerabilities as listed below. Software fixes can no longer be provided for The SENTRON 7KT PAC1260 Data Manager. This advisory documents the known open vulnerabilities. To fix the vulnerabilities, Siemens recommends to replace the device by the new SENTRON 7KT PAC1261 Data Manager and update it to the latest available firmware version.

  • WID-SEC-W-2025-0772Siemens SENTRON 7KT PAC1260 Data Manager: Mehrere SchwachstellenDeutsch2025-04-08csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Siemens Sentron PAC ausnutzen, um beliebigen Code mit administrativen Rechten auszuführen, Sicherheitsmaßnahmen zu umgehen, Daten zu manipulieren, erhöhte Rechte zu erlangen und vertrauliche Informationen preiszugeben.

  • ICSA-25-100-06Siemens SENTRON 7KT PAC1260 Data Manager2025-04-08icsa · cisa_csaf_otUS

    SENTRON 7KT PAC1260 Data Manager is affected by multiple vulnerabilities as listed below. Software fixes can no longer be provided for The SENTRON 7KT PAC1260 Data Manager. This advisory documents the known open vulnerabilities. To fix the vulnerabilities, Siemens recommends to replace the device by the new SENTRON 7KT PAC1261 Data Manager and update it to the latest available firmware version.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan