CVE-2024-39675
highpriority · track · 0EPSS 0.003 · 20 %ileDEEUNLRUUSEPSS · scored 2026-10-23
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedRUGGEDCOM RMC30siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RMC30NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RP110siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RP110NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS400siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS400NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS401siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS401NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCv2 V4.Xsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCv2 V5.Xsiemens_psirt
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416Psiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCv2 V4.Xsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCv2 V5.Xsiemens_psirt
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416Pv2 V4.Xsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416Pv2 V5.Xsiemens_psirt
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416v2 V4.Xsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416v2 V5.Xsiemens_psirt
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS910siemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS910NCsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS910Wsiemens_psirt
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RMC30cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RMC30NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RP110cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RP110NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS400cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS400NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS401cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS401NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCv2 V4.Xcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416NCv2 V5.Xcisa_csaf_ot
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416Pcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCv2 V4.Xcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416PNCv2 V5.Xcisa_csaf_ot
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416Pv2 V4.Xcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416Pv2 V5.Xcisa_csaf_ot
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS416v2 V4.Xcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS416v2 V5.Xcisa_csaf_ot
Update to V5.9.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972217/ - FixedRUGGEDCOM RS910cisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS910NCcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - FixedRUGGEDCOM RS910Wcisa_csaf_ot
Update to V4.3.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972218/ - MitigationRUGGEDCOM RMC30siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RMC30NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RP110siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RP110NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS400siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS400NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS401siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS401NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCv2 V4.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCv2 V5.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Psiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCv2 V4.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCv2 V5.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Pv2 V4.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Pv2 V5.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416v2 V4.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416v2 V5.Xsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910siemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910Lsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910LNCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910NCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910Wsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920Lsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920LNCsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920Wsiemens_psirt
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RMC30cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RMC30NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RP110cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RP110NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS400cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS400NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS401cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS401NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCv2 V4.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416NCv2 V5.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Pcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCv2 V4.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416PNCv2 V5.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Pv2 V4.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416Pv2 V5.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416v2 V4.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS416v2 V5.Xcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910cisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910Lcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910LNCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910NCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS910Wcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920Lcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920LNCcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- MitigationRUGGEDCOM RS920Wcisa_csaf_ot
Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default
- No fix plannedRUGGEDCOM RS910Lsiemens_psirt
Currently no fix is planned
- No fix plannedRUGGEDCOM RS910LNCsiemens_psirt
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920Lsiemens_psirt
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920LNCsiemens_psirt
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920Wsiemens_psirt
Currently no fix is planned
- No fix plannedRUGGEDCOM RS910Lcisa_csaf_ot
Currently no fix is planned
- No fix plannedRUGGEDCOM RS910LNCcisa_csaf_ot
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920Lcisa_csaf_ot
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920LNCcisa_csaf_ot
Currently no fix is planned
- No fix plannedRUGGEDCOM RS920Wcisa_csaf_ot
Currently no fix is planned
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.3–8.8
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (152)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- NCSC-2024-0282Kwetsbaarheden verholpen in Siemens ProductenNL2024-07-09csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.
- SSA-170375SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS Before V5.92024-07-09csaf · siemens_psirtDE
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-24-193-06Siemens RUGGEDCOM2024-07-09icsa · cisa_csaf_otUS
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
also known as (5)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (5)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/html/ssa-170375.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2024-39675/cnnvd
- https://vigilance.fr/vulnerability/Siemens-RUGGEDCOM-ROS-four-vulnerabilities-dated-09-07-2024-44683cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-170375.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-170375.htmlnvd