A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow an attacker to downgrade the device to older versions with known vulnerabilities.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedCPCI85 Central Processing/Communicationsiemens_psirt

    Update to V5.40 or later version The firmware CPCI85 V5.40 is present within “CP-8031/CP-8050 Package” V5.40

  • FixedSICORE Base systemsiemens_psirt

    Update to V1.4.0 or later version The firmware SICORE V1.4.0 is present within “SICAM 8 Software Solution Package” V5.40

  • FixedCPCI85 Central Processing/Communicationcisa_csaf_ot

    Update to V5.40 or later version The firmware CPCI85 V5.40 is present within “CP-8031/CP-8050 Package” V5.40

  • FixedSICORE Base systemcisa_csaf_ot

    Update to V1.4.0 or later version The firmware SICORE V1.4.0 is present within “SICAM 8 Software Solution Package” V5.40

02

cvss

Technical severity, 0–10. One row per scoring source.

7.1
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.9–7.1

v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · productcert@siemens.com DEexploitability 2.8 · impact 3.6
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · Siemens ProductCERT DE
v3.16.5mediumAV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · FSTEC (BDU) RU
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · CISA US
v4.07.1highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.1highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.04.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (12)

Products and version ranges known to be affected.

06

advisories (3)

Vendor and ecosystem advisories describing this.

  • SSA-071402SSA-071402: Multiple Vulnerabilities in SICAM Products2024-07-22csaf · siemens_psirtDE

    Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICAM EGS Device firmware - CPCI85 - SICAM 8 Software Solution - SICORE Siemens has released new firmware versions for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2024-1686Siemens SICAM: Mehrere SchwachstellenDeutsch2024-07-22csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Siemens SICAM ausnutzen, um seine Privilegien zu erhöhen oder die Firmware-Version herabzustufen.

  • ICSA-24-207-01Siemens SICAM Products2024-07-22icsa · cisa_csaf_otUS

    Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICAM EGS Device firmware - CPCI85 - SICAM 8 Software Solution - SICORE Siemens has released new firmware versions for the affected products and recommends to update to the latest versions.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan