CVE-2024-37367
highpriority · track · 30EPSS 0.005 · 42 %ileDEEURUUSEPSS · scored 2026-10-27
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
No vendor fix yet; a mitigation is available.
- MitigationFactoryTalk View SEcisa_csaf_ot
Rockwell Automation encourages users of the affected software, who are not able to upgrade to one of the corrected versions, to apply the risk mitigations where possible.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.6–8.6
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (5)
Products and version ranges known to be affected.
- rockwellautomation factorytalk view12.0 → 14.0nvdUScpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:*:*:*:*
advisories (2)
Vendor and ecosystem advisories describing this.
- WID-SEC-W-2024-1380Rockwell Automation FactoryTalk View SE: Mehrere SchwachstellenDeutsch2024-06-13csaf · cert_bundDE
Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in Rockwell Automation FactoryTalk View SE ausnutzen, um Informationen offenzulegen oder seine Privilegien zu erhöhen.
- ICSA-24-165-16Rockwell Automation FactoryTalk View SE2024-06-13icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could allow an outside attacker to view an HMI project.
also known as (5)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2024-37367/cnnvd
- https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.htmlcnnvd
- https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.htmlenisa_euvd
- https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.htmlBroken Linknvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan