CVE-2024-3640

mediumpriority · track · 10EPSS 0.003 · 19 %ileexploit · PoCDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
0.27% (19th) EPSS
CVSS 6.5 · medium
Is it mine?
4 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

An unquoted executable path exists in the Rockwell Automation FactoryTalk® Remote Access™ possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5.2–7

v3.16.5mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.16.5mediumAV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v4.07highCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.07highCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · PSIRT@rockwellautomation.com
v4.05.2mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

exploits (1)

Public proof-of-concept and weaponised exploit code.

06

affected products (4)

Products and version ranges known to be affected.

07

advisories (2)

Vendor and ecosystem advisories describing this.

  • WID-SEC-W-2024-1119Rockwell Automation FactoryTalk: Mehrere SchwachstellenDeutsch2024-05-14csaf · cert_bundDE

    Ein authentifizierter Angreifer kann mehrere Schwachstellen in Rockwell Automation FactoryTalk ausnutzen, um beliebigen Code auszuführen, Dateien zu manipulieren oder vertrauliche Informationen offenzulegen.

  • ICSA-24-135-01Rockwell Automation FactoryTalk Remote Access2024-05-14icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, resulting in remote code execution.

08

also known as (5)

Other names and identifiers for this entity.

09

sources

Which sources assert this record, and when.

10

references (4)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.