CVE-2024-24810
highpriority · track · 31EPSS 0.002 · 14 %ileDEEURUUSEPSS · scored 2026-10-27
WiX toolset lets developers create installers for Windows Installer, the Windows installation engine. The .be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges. This impacts any installer built with the WiX installer framework. This issue has been patched in version 4.0.4.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- Fixedwago_psirt
A fix is available with the WAGO Navigator 1.0.2 and is accessible through the WAGO download center.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (13)
Products and version ranges known to be affected.
advisories (2)
Vendor and ecosystem advisories describing this.
- VDE-2024-021WAGO: Vulnerability in WAGO Navigator2024-05-21csaf · wago_psirtDE
The WAGO Navigator versions 1.0.1 and 1.0 are vulnerable due to the use of the WiX toolset version 3.11.2.
- GHSA-7wh2-wxc7-9ph5WiX Toolset's .be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges2024-02-08ghsa · osvUS
### Summary .be TEMP folder is vulnerable to DLL redirection attacks that allow the attacker to escalate privileges. ### Details If the bundle is not run as admin, the user's TEMP folder is used and not the system TEMP folder. A utility is able to monitor the user's TEMP folder for changes and drop its own DLL into the **.be/<bundle>.Local** folder immediately when the .be folder is created. When the burn engine elevates, the malicious DLL receives elevated privileges. ### PoC As a standard, non-admin user: 1. Monitor the user's TEMP folder for changes using ReadDirectoryChangesW 2. On FILE_ACTION_ADDED, check if the folder name is .be 3. Create a folder in .be named after the bundle + .Local (e.g. MyInstaller.exe.Local) 4. Put the malicious COMCTL32.DLL in the .Local folder following the naming used for the real DLL (e.g. MyInstaller.exe.Local/x86_microsoft.windows.common-controls_.../COMCTL32.dll) 5. Do hacker things when the engine escalates and the malicious DLL is loaded Proper naming for the path can be obtained by using GetModuleHandle("comctl32.dll") and GetModuleFileName. ### Impact DLL redirection utilizing .exe.Local Windows capability. This impacts any installer built with the WiX installer framework.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2024-24810/cnnvd
- https://github.com/wixtoolset/issues/security/advisories/GHSA-7wh2-wxc7-9ph5cnnvd
- https://github.com/wixtoolset/issues/security/advisories/GHSA-7wh2-wxc7-9ph5enisa_euvd
- https://github.com/wixtoolset/issues/security/advisories/GHSA-7wh2-wxc7-9ph5Vendor Advisorynvd