CVE-2024-24806

highpriority · track · 30EPSS 0.020 · 81 %ileDEEUFRNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
2.00% (81st) EPSS
CVSS 7.3 · high
Is it mine?
80 products
Check your exposure
Who says so?
8 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-27

libuv is a multi-platform support library with a focus on asynchronous I/O. The `uv_getaddrinfo` function in `src/unix/getaddrinfo.c` (and its windows counterpart `src/win/getaddrinfo.c`), truncates hostnames to 256 characters before calling `getaddrinfo`. This behavior can be exploited to create addresses like `0x00007f000001`, which are considered valid by `getaddrinfo` and could allow an attacker to craft payloads that resolve to unintended IP addresses, bypassing developer checks. The vulnerability arises due to how the `hostname_ascii` variable (with a length of 256 bytes) is handled in `uv_getaddrinfo` and subsequently in `uv__idna_toascii`. When the hostname exceeds 256 characters, it gets truncated without a terminating null byte. As a result attackers may be able to access internal APIs or for websites (similar to MySpace) that allows users to have `username.example.com` pages. Internal services that crawl or cache these user pages can be exposed to SSRF attacks if a malicious user chooses a long vulnerable username. This issue has been addressed in release version 1.48.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.3
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.7–7.3

v3.17.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lprimary · NVD / NIST USexploitability 3.9 · impact 3.4
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lsecondary · CISA US
v3.17.3highAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lsecondary · FSTEC (BDU) RU
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lsecondary · ENISA EU
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lsecondary · security-advisories@github.comexploitability 3.9 · impact 3.4
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:Lsecondary · Siemens ProductCERT DE
v3.16.7mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: poc · Automatable: no · Technical Impact: partialcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (80)

Products and version ranges known to be affected.

showing 20 of 80
06

advisories (7)

Vendor and ecosystem advisories describing this.

  • NCSC-2024-0433Kwetsbaarheden verholpen in Siemens productenNL2024-11-12csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDCOM, SCALANCE, SIMATIC en SINEC.

  • SSA-915275SSA-915275: Multiple Vulnerabilities in SINEC INS Before V1.0 SP2 Update 32024-11-12csaf · siemens_psirtDE

    SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.

  • WID-SEC-W-2024-0393Node.js: Mehrere SchwachstellenDeutsch2024-02-14csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Node.js ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, einen Denial-of-Service-Zustand zu verursachen, vertrauliche Informationen offenzulegen, Dateien zu manipulieren oder seine Privilegien zu erweitern.

  • WID-SEC-W-2024-0540IGEL OS: Schwachstelle ermöglicht Umgehen von SicherheitsvorkehrungenDeutsch2024-03-04csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann eine Schwachstelle in IGEL OS ausnutzen, um Sicherheitsvorkehrungen zu umgehen.

  • WID-SEC-W-2024-1248Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2024-05-28csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden

  • ICSA-24-319-08Siemens SINEC INS2024-11-12icsa · cisa_csaf_otUS

    SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.

  • CERTFR-2026-AVI-1385Multiples vulnérabilités dans les produits VMwareFrançais2026-10-26vendor · certfrFR
07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (33)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan