CVE-2023-5778
highpriority · track · 0EPSS 0.003 · 20 %ileCHEPSS · scored 2026-10-22
Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900. This issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version <=Freelance 2013 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2016 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 installed with ABB Freelance Controller AC700abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 installed with ABB Freelance Controller AC800abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 installed with ABB Freelance Controller AC900abb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- FixedABB System Version Freelance 2019 installed with ABB Freelance Controller DCPabb_psirt
The Freelance system shall be used as described in the manual 3BDD012560-111 “Getting Started” chapter 1.2.6. The issue is corrected in following product versions: • Freelance 2013 SP1 RU06 and higher RUs for that version • Freelance 2016 SP1 RU07 and higher RUs for that version • Freelance 2019 SP1 RU03 and higher RUs for that version This vulnerability is corrected in the product versions from Freelance 2019 SP1 FP1 on. This vulnerability does not exist with Freelance 2019 SP1 FP1 and later. ABB recommends that customers apply the update at earliest convenience. Users who are unable to install the updates should immediately look to implement the Mitigation listed as this will block an attacker’s ability to compromise their installations.
- MitigationABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version <=Freelance 2013 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2016 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 installed with ABB Freelance Controller AC700abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 installed with ABB Freelance Controller AC800abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 installed with ABB Freelance Controller AC900abb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- MitigationABB System Version Freelance 2019 installed with ABB Freelance Controller DCPabb_psirt
Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.
- WorkaroundABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version <=Freelance 2013 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version <=Freelance 2013 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2013 SP1 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 SP1 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2016 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 SP1 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 installed with ABB Freelance Controller AC700abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 installed with ABB Freelance Controller AC800abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 installed with ABB Freelance Controller AC900abb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
- WorkaroundABB System Version Freelance 2019 installed with ABB Freelance Controller DCPabb_psirt
For Freelance system version >= Freelance 2016 and Freelance controllers AC 700 and AC 900 (by using the Display Unit) there is the possibility to activate the Download-Protection (disabled Download) on the controller. Download-Protection for the AC 700 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “8.3.2 Online functions” / “8.3.2 Online-Funktionen” section look for the desired action “Locking the AC 700F for application and firmware downloads” / “AC 700F für Applikations und Firm-ware-Download sperren”. When the locking is enabled the controller is not vulnerable any more against this know issue. Download-Protection for the AC 900 Controller: Use the “Mounting_and_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (Englisch) or “Montage_und_Installation_AC_700F_Controller” / “M&I - AC 700F Controller” (German) User Manual PDF. In the “Section 8 - Service -> Online functions of the display unit -> Controller menu -> F2 - Security -> F2 function: Download enabled/disabled” / “Kapitel 8 - Service -> Online-Funktionen der Display-Unit -> Controller-Menü -> F2 - Security -> Funktion F2: Download freigegeben/gesperrt” there is the Download-Protection described. When the Download is disabled the controller is not vulnerable any more against this know issue.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.5–9.2
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (44)
Products and version ranges known to be affected.
advisories (1)
Vendor and ecosystem advisories describing this.
- 7PAA010706Freelance Missing Length Check2026-09-18csaf · abb_psirtCH
ABB is aware of a vulnerability in the product versions listed as affected in the advisory. An update is available that resolves the reported vulnerability in the product versions under maintenance. An attacker who successfully exploited this vulnerability could cause the product to stop or make the product inaccessible.
sources
Which sources assert this record, and when.
references (1) nvd
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan