CVE-2023-44374

highpriority · track · 35EPSS 0.007 · 52 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.67% (52nd) EPSS
CVSS 8.8 · high
Is it mine?
292 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

8.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.9–8.8

v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 2.8 · impact 5.9
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · productcert@siemens.com DEexploitability 2.8 · impact 3.6
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · Siemens ProductCERT DE
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · CISA US
v3.16.5mediumAV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Nsecondary · FSTEC (BDU) RU
v4.04.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
v4.07.1highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.07.1highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (292)

Products and version ranges known to be affected.

06

advisories (7)

Vendor and ecosystem advisories describing this.

  • NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.

  • SSA-180704SSA-180704: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.02023-12-12csaf · siemens_psirtDE

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • SSA-690517SSA-690517: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11ax Family2024-06-11csaf · siemens_psirtDE

    SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11ax family and recommends to update to the latest version. Siemens recommends countermeasures for vulnerabilities where fixes are not, or not yet available.

  • SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-348-14Siemens RUGGEDCOM and SCALANCE M-800/S615 Family2023-12-12icsa · cisa_csaf_otUS

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-165-12Siemens SCALANCE W7002024-06-11icsa · cisa_csaf_otUS

    SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11ax family and recommends to update to the latest version. Siemens recommends countermeasures for vulnerabilities where fixes are not, or not yet available.

07

also known as (6)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (16)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan