CVE-2023-44373

criticalpriority · track · 0EPSS 0.013 · 71 %ileDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.34% (71st) EPSS
CVSS 9.1 · critical
Is it mine?
412 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.4
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.6–9.4

v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · NCSC-NL NL
v3.19.1criticalAV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 2.3 · impact 6
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v4.09.4criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:Hsecondary · ENISA EU
v4.09.4criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.6highCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (412)

Products and version ranges known to be affected.

05

advisories (12)

Vendor and ecosystem advisories describing this.

  • NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.

  • NCSC-2026-0112Kwetsbaarheden verholpen in Siemens productenNL2026-04-14csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Analytics Toolkit, Ruggedcom, Industrial Edge Management Pro, SIDIS en TPM.

  • SSA-019200SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.02026-04-14csaf · siemens_psirtDE

    SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.

  • SSA-180704SSA-180704: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.02023-12-12csaf · siemens_psirtDE

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • SSA-602936SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.12024-02-13csaf · siemens_psirtDE

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • SSA-721642SSA-721642: Injection Vulnerability in SCALANCE W700 802.11 AX Family Before V2.42024-09-10csaf · siemens_psirtDE

    Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-348-14Siemens RUGGEDCOM and SCALANCE M-800/S615 Family2023-12-12icsa · cisa_csaf_otUS

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-046-09Siemens SCALANCE SC-600 Family2024-02-13icsa · cisa_csaf_otUS

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-256-13Siemens SCALANCE W7002024-09-10icsa · cisa_csaf_otUS

    Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-26-111-07Siemens SCALANCE2026-04-14icsa · cisa_csaf_otUS

    SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.

06

also known as (6)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

08

references (25)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan