A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

5.4
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USexploitability 2.3 · impact 2.7
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.15.4mediumAV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · FSTEC (BDU) RU
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · ENISA EU
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:Nsecondary · productcert@siemens.com DEexploitability 1.6 · impact 2.7
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.15mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (6)

Products and version ranges known to be affected.

06

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-160243SSA-160243: Multiple Vulnerabilities in SINEC NMS before V2.02023-10-10csaf · siemens_psirtDE

    SINEC NMS before V2.0 is affected by a code injection and a stored cross-site scripting vulnerability. Siemens has released an update for SINEC NMS and recommends to update to the latest version.

  • ICSA-23-285-08Siemens SINEC NMS2023-10-10icsa · cisa_csaf_otUS

    SINEC NMS before V2.0 is affected by a code injection and a stored cross-site scripting vulnerability. Siemens has released an update for SINEC NMS and recommends to update to the latest version.